ABB i-bus
KNX
Device technology
SA/S | 2CDC 505 056 D0208 41
2.7
Overview of switching performance
The following table shows the switching capacities, lamp loads and/or the number of lamps that can be
connected to each contact.
SA/S 4.6.1.1
SA/S 8.6.1.1
SA/S 12.6.1.1
SA/S 2.6.2.1
SA/S 4.6.2.1
SA/S 8.6.2.1
SA/S 12.6.2.1
SA/S 2.10.2.1
SA/S 4.10.2.1
SA/S 8.10.2.1
SA/S 12.10.2.1
SA/S 2.16.2.1
SA/S 4.16.2.1
SA/S 8.16.2.1
SA/S 12.16.2.1
SA/S 2.16.5.1
SA/S 4.16.5.1
SA/S 8.16.5.1
SA/S 12.16.5.1
SA/S 2.16.6.1
SA/S 4.16.6.1
SA/S 8.16.6.1
SA/S 12.16.6.1
I
n
rated current (A)
6 A
6 AX
10 AX
16 A
16/20 AX C-
load
16/20 AX C-
load
U
n
rated voltage (V)
250/440 V AC
250/440 V AC
250/440 V AC
250/440 V AC
250/440 V AC
250/440 V AC
AC1 operation (cos
ϕ
= 0.8) EN 60 947-4-1
6 A
6 A
10 A
16 A
20 A
20 A
AC3 operation (cos
ϕ
= 0.45) EN 60 947-4-1
6 A
6 A
8 A
–
4)
16 A
16 A
C-load switching capacity
–
–
–
–
20 A
20 A
Fluorescent lighting load AX to EN 60 669-1
6 A (35
µF)
3)
6 AX (140 µF)
3)
10 AX (140 µF)
3)
16 A (70 µF)
3)
20 AX (200 µF)
3)
20 AX (200 µF)
3)
Minimum switching capacity
10 mA/12 V
100 mA/12 V
100 mA/12 V
100 mA/12 V
100 mA/12 V
100 mA/12 V
DC current switching capacity
(ohmic load)
7 A/24 V =
6 A/24 V =
10 A/24 V =
16 A/24 V =
20 A/24 V =
20 A/24 V =
Mechanical lifetime
> 10
7
> 3 x 10
6
> 3 x 10
6
> 3 x 10
6
> 10
6
> 10
6
Electrical endurance to
IEC 60947-4-1:
– Rated current AC1 (240V/0.8)
– Rated current AC3 (240V/0.45)
– Rated current AC5a (240V/0.45)
100,000
15,000
15,000
100,000
30,000
30,000
100,000
30,000
30,000
100,000
30,000
30,000
100,000
30,000
30,000
100,000
30,000
30,000
Incandescent lamp load at 230 V AC
1,200 W
1,380 W
2,500 W
2,500 W
3,680 W
3,680 W
Fluorescent lamps T5/T8:
– Uncompensated
– Parallel compensated
– DUO circuit
800 W
300 W
350 W
1,380 W
1,380 W
1,380 W
2,500 W
1,500 W
1,500 W
2,500 W
1,500 W
1,500 W
3,680 W
2,500 W
3,680 W
3,680 W
2,500 W
3,680 W
Low-voltage halogen lamps
– inductive transformer
– electronic transformer
800 W
1,000 W
1,200 W
1,380 W
1,200 W
1,500 W
1,200 W
1,500 W
2,000 W
2,500 W
2,000 W
2,500 W
Halogen lamps 230 V
1,000 W
1,380 W
2,500 W
2,500 W
3,680 W
3,680 W
Dulux lamps (energy-saving lamps):
– Uncompensated
– Parallel compensated
800 W
800 W
1,100 W
1,100 W
1,100 W
1,100 W
1,100 W
1,100 W
3,680 W
3,000 W
3,680 W
3,000 W
Mercury-vapor lamps:
– Uncompensated
– Parallel compensated
1,000 W
800 W
1,380 W
1,380 W
2,000 W
2,000 W
2,000 W
2,000 W
3,680 W
3,000 W
3,680 W
3,000 W
Sodium vapor lamps:
– Uncompensated
– Parallel compensated
1,000 W
800 W
1,380 W
1,380 W
2,000 W
2,000 W
2,000 W
2,000 W
3,680 W
3,000 W
3,680 W
3,000 W
Max. peak inrush current I
p
(150
µ
s)
Max. peak inrush current I
p
(250
µ
s)
Max. peak inrush current I
p
(600
µ
s)
200 A
160 A
100 A
400 A
320 A
200 A
400 A
320 A
200 A
400 A
320 A
200 A
600 A
480 A
300 A
600 A
480 A
300 A
Number of electronic ballasts
(T5/T8, single element):
2)
18 W (ABB EVG 1 x 18 CF)
24 W (ABB EVG 1 x 24 CY)
36 W (ABB EVG 1 x 36 CF)
58 W (ABB EVG 1 x 58 CF)
80 W (Helvar EL 1 x 80 SC)
10 EBUs
10 EBUs
7 EBUs
5 EBUs
3 EBUs
23 EBUs
23 EBUs
14 EBUs
11 EBUs
10 EBUs
23 EBUs
23 EBUs
14 EBUs
11 EBUs
10 EBUs
23 EBUs
23 EBUs
14 EBUs
11 EBUs
10 EBUs
26
1)
EBUs
26
1)
EBUs
22 EBUs
12
1)
EBUs
12
1)
EBUs
26
1)
EBUs
26
1)
EBUs
22 EBUs
12
1)
EBUs
12
1)
EBUs
1)
The number of ballasts (EBUs)
is limited by protection with B16/20 A circuit-breakers.
2)
For multiple element lamps or other types the number of electronic ballasts must be determined using the peak inrush current of the ballasts.
3)
The maximum inrush current peak may not be exceeded.
4)
Not intended for AC3 operation; maximum AC3 current see
Technical data
, from p. 9.