2.2.3. Communication glass fiber cable
The CAN and Ethernet communication between the Power Cabinet and Charge control set
is done via a glass fiber cable. This glass fiber cable must be prefabricated and can be
ordered separately.
Cable length must be defined by the contractor performing installation during site survey.
Amount
Part number
Description
1
OM3, prefabricated
OM3, PCF or fiberglass (multimode, 850 nm) optic cable with
8 fibers (4 for spare), with B-FCO(ST
®
) connectors
2.2.4. Electrical components
Emergency unit
Integrated in the pole, but need to be ordered separately if ordered without pole.
Amount Part number
Description
1
1SFA619550R1051
CE4T-10R-02 Emergency stop button
1
1SFA619811R1000
CEP1-0 Enclosure
Distance sensor
Integrated in the pole, but need to be ordered separately if ordered without pole.
Amount Part number
Description
1
UT1B/E9-0AUL
Ultrasonic Sensor (Welotec)
RFID unit
Needed when multiple Charge control sets are installed close to each other.