Table 3.7/11:
Analogue inputs Armature converter mode (DCS600)
Analogue inputs
Depending on the drive modes there are different
possibilities for analogue inputs.
II F 3-14
Analogue Inputs
Armature converter mode
Channel used for signal through:
Channel
AITAC
AI1
AI2
AI3
AI4
Accuracy
± 4096
± 4096
± 2048
± 2048
± 2048
Signal
FIELD_CUR_ACT
3.19
(used for Rebuild Appl.)
FEXC_SEL
15.05=9
FEXC_SEL
15.05=10
FEXC_SEL
15.05=11
FEXC_SEL
15.05=12
FEXC_SEL
15.05=13
SPEED_ACT
1.02
SPEED_MEAS_MODE
50.03=4
MOT1_MEAS_TEMP
1.22
MOT1_TEMP_AI_SEL
28.09=1...5
MOT2_MEAS_TEMP
1.23
MOT2_TEMP_AI_SEL
28.12=1...5
EARTH_CURRENT
(Fault)
EARTH_CUR_SEL
28.19=1
TQCORR
2.14
AI1_VAL_SEL
13.16=1
Speed ref
AI SPEED SELECT
13.17=5
AI SPEED SELECT
13.17=1
AI SPEED SELECT
13.17=2
AI SPEED SELECT
13.17=3
AI SPEED SELECT
13.17=4