II F 2-24
Connection example in accordance with EMC
Fig. 2.6/6: Connection example in accordance with EMC
Important hint:
The example shows the principle structure of
a DC drive and its connections. It is a not
binding recommendation, and it cannot re-
spect all conditions of a plant. Therefore
each drive must be considered separately
and with respect to the special application.
Additionally the general installation and safety
rules must be taken in account.
M
A1 A2
F1
F2
A1 A2
F1
F2
L1
L2
L3
PE
U1
V1
W1
C1
D1
1
7
5
3
PE
PE
PE
PE
A
F
A
F
Tacho
A
F
Tacho
T
I/
O
Mounting plate
DC motor
Tac
h
o
Screens
Contact to the motor
housing at the whole
screen perimeter
Filter
Mounting plate with PE
bar and terminals
PE bar
DC motor
Tac
h
o
Sc
re
e
n
Mounting plate with PE
bar and terminals
PE bar
lower edge
of the PCB
carrier
Encoder inputs and
analogue I/O at the PCB
Field
supply
unit
Armature and field
cables with
screens for
"first environment"
Armature and field
cables without
screens suitable for
"second