II K 4-1
Overview of Software
4
Overview of software
(The software delivered may contain minor changes to the product described here.)
Parameter
The parameters of the converter are subdivided into
functional groups. These groups are listed in the table
below.
Parameter group
Functions
1 - Motor Settings
Motor settings, actual line
values, auto reclosing
2 - Operating Mode
Macro selection, behaviour
during switching on/off, con-
trol/status information, con-
trol location
3 - Armature
Actual value signals, high
current dosage, controller
settings, stall protection, ref-
erence sources
4 - Field
Actual value signals, con-
troller settings, overcurrent/
undercurrent tripping, flux
adaptation, field heating
5 - Speed Controller
Reference sources, actual
value acquisition, controller
settings, ramp generator,
constant speeds, alternative
settings, speed monitoring,
actual value filtering
6 - Input/Output
Scaling and allocation of the
analog and digital inputs and
outputs, display selection for
the control panel, field bus
allocation, actual value sig-
nals
7 - Maintenance
Language selection, service
procedures, diagnostics,
fault and alarm information,
square-wave generator
8 - Field Bus
Serial communication via the
field bus, RS232 or panel
adapter
9 - Macro Adaptation
Re-configure digital inputs
DI1...DI4 of macros 1, 5, 6,
7, and 8.
Function menu
Special functions of the control panel are listed in the
table below.
Menu function
Significance
Set Typecode
Typecode adaptation for re-
placement of SDCS-CON-3
Read Faultlogger
Read / Clear the last 16
Faults or Alarms
Factory Settings
Reset all parameters to fac-
tory values (default values)
Copy to Panel
Parameter uploading from
drive to control panel
Copy to Drive
Parameter downloading
from control panel to drive
Long/Short Par List
Some parameter visible / in-
visible
Panel Lock
Lock the control panel for
maloperation
LCD Contrast
Contrast of cotrol panel dis-
play
Commissioning
Guided commissioning via
control panel
Parameter saving
Any changes of the parameters are stored auto-
matically in the FlashProm of the converter. The
storage is executed in a time interval of approx. 5
seconds.
Continual parameter writing destroys the Flash-
Prom
Parameter are saved automatically in a background
routine. This is done approx. every 5 seconds, when:
• parameters are altered by means of the
control
panel
.
• parameters are transmitted by means of PC Tool
Drive Window Light
, irrespective of whether the
content of the parameter has changed.
• parameters are transmitted by means of
PLC
communication via one of the three serial ports
Field bus adapter
or
RS232-Port
or
Panel-
Port
, irrespective of whether the parameter’s
content has changed.
Continual transmission
of a parameter with the
same content will entail
continual saving
in the
background routine, i.e. even if the value of the
parameter does not change, the save routine will still
be activated.
A FlashProm of the present-day generation can be
written on and erased up to 100,000 times. This
means 100,000 x 5 seconds = approx. 6 days.
Continual transmission of parameters may de-
stroy this FlashProm after approx. 6 days, which
is why parameters should only be transmitted if
the values involved have changed.
Содержание DCS 400
Страница 1: ...II K 1 1 DCS Thyristor power converter for DC drive systems 20 to 1000 A 9 to 522 kW Manual DCS 400 ...
Страница 24: ...II K 3 14 Technical data ...
Страница 29: ...II K 4 5 Overview of Software ...
Страница 158: ...II K 6 36 Operating Instructions ...
Страница 181: ...II K B 1 Appendix B Declaration of conformity ...
Страница 190: ...Notices ...
Страница 191: ...Notices ...