![ABB Advant Controller 450 Скачать руководство пользователя страница 214](http://html.mh-extra.com/html/abb/advant-controller-450/advant-controller-450_user-manual_3016214.webp)
Advant
®
Controller 450 User’s Guide
Chapter 2 Installation
2-60
3BSE 002 415R701 Rev A
Data Set Peripheral
Yes
CRDB
DSP
DSP_x
Demand Basic cycle time can be
changed via APP command
PROFIBUS-DP:
--PROFIBUS Slave
--PROFIBUS Slave
Descr.
Yes
CRDB
CRDB
CRDB
CI541
PBS
PBSD
PBx
PBSx
PBSDx
Demand
Demand
Demand
LONWORKS:
LONWORKS Device
LONWORKS Network
variable of input type
LONWORKS Network
variable of output type
LONWORKS Multiple
network variable
LONWORKS Event
treatment
LONWORKS Multiple
references
Yes
Yes
Yes
Yes
Yes
Yes
No
CRDB
CRDB
CRDB
CRDB
CRDB
CRDB
CRDB
LON
LONDEV
LONNVI
LONNVO
LONMNVI
LONEVTR
LONMREF
LONx
LONDEVx
LONNVx
LONNVx
LONMNVIx
LONEVTRx
LONMREFx
Demand
Demand
Demand
Demand
Demand
Demand
Demand
When LON is created it
automatically creates 2
LONCHAN channel data
base elements, specify type
CI572 or CI573.
EXCOM
No
CRDB
CI531
RS232_x
Demand When config. of CI531 the
disposition of HW module
CI531 channel 1,2 is entered.
Possible values are:
PRI_01, XCOM_1, XCOM_2,
TERM_1, .....TERM_4
V.24/RS-232-C
(Terminal, Printer)
No
CRDB
CI531
RS232_x
Demand
RCOM
No
CRDB
CI532
MVIx
Demand Function variant, RCOM or
MVI type, is defined by the
used hardware module. For
example RCOM uses
CI532V01
MultiVendor Interface
(Standard protocol)
Yes
CRDB
CI532 or
MVIMOD
(6)
MVIx
Demand
MVI Free-programmable
communication
Yes
CRDB
CI535 or
MVIMOD
MVIx
Demand DB element CI535 for module
CI535 and MVIMOD for
module CI538
(1) CRDB stands for the engineering tool command CReate Data Base.
(2) No data entry means that default values exist and it is not necessary to enter any data. User-unique names can be introduced if
desirable.
(3) The call name is used in connection to command CRDB.
A parenthesized ( ) call name indicates that the call name cannot be used with the command CRDB.
(4) The item designation (default name) or a user-defined name is used to access an element
with the command MDB, Modify Data Base. The item designation can always be used,
independent of whether or not a user-defined name exists
(5) Miscellaneous refers to different elements for different I/O board, I/O unit or I/O module types.
(6) Depending on protocol.
Table 2-13. Function List with an Outline of Controller System Configuration Information. (Continued)
Function/
occurrence
Dimen-
sioning
Creating
(1)
Data Base Element
Data
entry
(2)
Comments
Call name
(3)
Item. design.
(default name)
(4)
Содержание Advant Controller 450
Страница 1: ...Advant OCS with Master software GYDQW RQWUROOHU User s Guide 3BSE 002 415R701 Rev A ...
Страница 26: ...Advant Controller 450 User s Guide Table of Contents 3BSE 002 415R701 Rev A xvi ...
Страница 30: ...Advant Controller 450 User s Guide Table of Contents 3BSE 002 415R701 Rev A xx ...
Страница 488: ... GYDQW RQWUROOHU 8VHU V XLGH SSHQGL DUGZDUH 0RGXOHV A 48 3BSE 002 415R701 Rev A ...
Страница 496: ...Advant Controller 450 User s Guide Appendix C Delivery Documentation C 2 3BSE 002 415R701 Rev A ...
Страница 508: ...Advant Controller 450 User s Guide Appendix D Item Designations D 12 3BSE 002 415R701 Rev A ...
Страница 514: ...Advant Controller 450 User s Guide Appendix E Current Consumption and Heat Dissipation E 6 3BSE 002 415R701 Rev A ...
Страница 518: ...Advant Controller 450 User s Guide Appendix F Load Calculation F 4 3BSE 002 415R701 Rev A ...
Страница 522: ...Advant Controller 450 User s Guide Appendix G Memory Calculation G 4 3BSE 002 415R701 Rev A ...
Страница 528: ...Advant Controller 450 User s Guide Appendix H Halt Codes H 6 3BSE 002 415R701 Rev A ...
Страница 561: ...Advant Controller 450 User s Guide Index 3BSE 002 415R701 Rev A iii V Valve control 1 102 VT100 terminal 1 105 ...
Страница 562: ...Advant Controller 450 User s Guide Index iv 3BSE 002 415R701 Rev A ...
Страница 563: ......
Страница 564: ...3BSE 002 415R701 Rev A March 2000 ...