06 MECHANICAL INSTALLATION
3BHS206977 E01 REV H
ACS1000I AIR-COOLED
USER MANUAL
82/174
6.4
Preparing the floor
Condition of the floor:
- Must support the weight of the cabinet
- Overall incline across 5 m must not exceed 5 mm
- Even
- Non-flammable, smooth and non- abrasive
- Protected against humidity diffusion
6.5
Fixing the cabinet to the floor
1. Drill fixing holes into the floor as indicated on the layout drawing.
Figure 6-1: Position of mounting holes
Important:
If the doors of medium voltage compartments cannot be opened,
contact the ABB service organization.