Group 99: Start-up Data
The Start-up Data parameters are a special set of parameters for setting up
the ACS 140 and for entering motor information.
Figure 1 Output voltage as a function of output frequency.
Code Description
9902
APPLIC MACRO
Application macro selection. This parameter is used to select the Application
Macro which will configure the ACS 140 for a particular application. Refer to
Application Macros
,
starting page 13, for a list and description of available
Application Macros.
9905
MOTOR NOM VOLT
Nominal motor voltage from motor rating plate. This parameter sets the
maximum output voltage supplied to motor by ACS 140.
MOTOR
NOM
FREQ
sets
the frequency at which output voltage is equal to the
MOTOR
NOM
VOLT
. The
ACS 140 cannot supply the motor with a voltage greater than the mains voltage.
See Figure 8.
9906
MOTOR NOM CURR
Nominal motor current from rating plate. The allowed range is 0.5 · I
N
... 1.5 · I
N
of ACS 140.
9907
MOTOR NOM FREQ
Nominal motor frequency from rating plate (field weakening point).
See Figure 8.
9908
MOTOR NOM SPEED
Nominal motor speed from rating plate.
Output voltage
Output frequency
MOTOR
NOM
VOLT
MOTOR
NOM
FREQ