3.2 Inspection
The SBC329 is shipped from Abaco with no jumpers fitted.
3.3 Link Descriptions
NOTES
1.
Ordinary operation requires no jumpers to be fitted.
2.
Software can read the state of the links from the FPGA.
3.
Additional jumper link functions are provided by an on-board EEPROM DIP switch device.
See
.
TIP
If you are about to install your board and power-up for the first time, leaving your board in the
default configuration will enable board operation to be proven before tackling any further
configuration issues.
3.3.1
Recovery Boot Link (P3)
This link allows user selection of the SPI Flash device from which the SBC329 boots,
as follows:
Table 3-1 P3 Link Setting
Setting Meaning
In
SBC329 boots from Recovery device
Out
SBC329 boots from Main device (default)
In normal operation, a jumper is not fitted on this link, and the SBC329 boots from
the Main device.
The Abaco-programmed Recovery device is for use if the Main device is corrupted.
Booting from the Recovery device puts the SBC329 into Recovery mode. Here, on-
board configuration EEPROMs are disabled, allowing devices to come up using
default strapping.