CIRCUMSTANCES
ELECTRICAL FAILURE OR ANY HYDRAULIC LINE FAILURE
PREPARATION BEFORE PROCEEDING
1)
CLEAR
OBSTACLES UNDERNEATH OF
HOIST
.
2)
TURN THE POWER SWITCH OFF.
3)
NEVER ENTER UNDER THE
HOIST
DURING THE PROCEDURE.
4)
MAKE SURE SAFETY DEVICE ON 4 POSTS IS DISABLED.
5)
IF THE SAFETY DEVICE IS
ON
LOCKED
POSITION, USE JAC
K
TO
LIFT THE
PLATFORM
AND
DISABLE THE DEVICE.
**
NEVER ALLOW ANY PERSON ENTERING
UNDER
HOIST
WHILE
PERFORMING THIS PROCEDURE
PROCEDURE
IF YOU HAVE ANY DOUBT FOR PERFORMING THIS
OPERATION,
CONTACT TRAINED PERSONNEL.
Emergency Decending
AFTER COMPLETION
REPOSITION ALL THE BOLTS AND NUTS INCLUDING EMERGENCY COCK VALVE TO ITS
ORIGINAL POSITION AND COVER THE PANEL
** FOLLOW SAME PROCEDURE FOR JACK BRIDGES AS ABOVE .
1)
MAKE SURE THE SAFETY LOCK ON JACK BRIDGE IS CANCELLED
* If it is engaged, use garage jack and lever and push top part of the jack bridge and release safety
lock.
2)
INSTEAD OF LOOSENING 2 LOOSEN EITHER 3 OR 4 JACK BRIDGE RELEASE VALVE IN STEP
OF ABOVE PROCEDURE