Installation
Only skilled technicians, appointed by the manufacturer, or by authorized dealers, must
be allowed to carry out installation. Serious damage to people and to the
hoist
can be
caused if installations are made by unskilled personnel.
Before carrying out any operations, remember to insert the safety piece of wood
between the lower booms and the base frame.
Checking for room suitability
The
hoist
has been designed to be used in covered and sheltered places free of overhead
obstructions. The place of installation must not be next to washing areas, painting workbenches,
solvent or varnish deposits. The installation near to rooms, where a dangerous situation of
explosion can occur, is strictly forbidden. The relevant standards of the local Health and Safety
at Work regulations, for instance, with respect to minimum distance to wall or other equipment,
escapes and the like, must be observed.
Lighting
Lighting must be carried out according to the effective regulations of the place of installation. All
area next to the
hoist
must be well and uniformly light.
Installation surface
The
hoist
must be placed on level floor and sufficiently resistant. The surface must be suitable
for bearing maximum stress values, also in unfavorable working conditions. For installations on
raised surface, compliance with the maximum carrying capacity of the surface is recommended.
A level floor is suggested for proper installation. Small differences in floor slope
may be compensated for by proper shimming. Any major slope change will affect
the level lifting performance. If a floor is of questionable slope (more than
3mm side to side or 5mm within the fill length of
hoist
), considering to pour
the new concrete slab.
10
Содержание AutoLift AL-6000A
Страница 10: ...Dimensions AL 6000S2 9 ...
Страница 18: ...Parts List 17 ...
Страница 19: ...18 ...
Страница 25: ...Air Line Diagram 24 ...
Страница 26: ...Electric motor jumper pins 25 ...
Страница 27: ...26 ...
Страница 28: ...How to operate Jack 27 ...