23
GDED-IOM-215-A
differential pressure across the filter elements and dust cake. Rising pressure on the gauge
shows that dust is being collected. When the gauge shows 2-3 in W.G., the fan damper or
blast gates may be adjusted to their normal position. At this time, the power to the timer
should be turned on.
Check the controller again. It should read between 2 to 3” w.g. with slight fluctuations
each time a pulse occurs. This indicates that the factory setting of the differential pressure,
or timer, is correct. Excessive pulsing can cause premature cartridge wear. On demand
pulse units do not change on time pulsing interval, but instead change the pressure settings.
11.2
Normal operation
The operation of the OptiFlo RC is fully automatic and does not require constant
supervision.
The OptiFlo RC is assumed to be part of a system that will include a fan and possibly
other components, supplied by AAF or other companies.
For successful operation of the OptiFlo RC, it must be ensured that:
1.
A suitable, dry compressed air supply to the compressed air manifold(s) is
available and connected to the collector at all times.
2.
The power supply to the pulse controller is on.
3.
There is awareness of the operation of the dust disposal equipment so that
collected dust is not retained in the hopper(s).
4.
The fan is operating at the specified conditions.
A record of operational data should be made and kept up to date. This is covered in
the maintenance section of this manual.
12
RECOMMENDED MAINTENANCE
12.1
Record Keeping
It is suggested that a record is kept of operational data and that all servicing
maintenance is recorded. A maintenance log is included in this IOM.