Make certain that the housing is safely positioned onto the hoppers/supporting steel
structure and that it cannot possibly fall should there be a failure of the lifting supports.
Secure the housing to the hopper with the bolts and washers that are supplied.
All the bolts must be tightened. The lifting equipment can now be removed.
NOTE: Check all access panels on the OptiFlo RC, including the top inlet panel, front
inlet panel, and the side outlets, to ensure these are caulked. If these are not caulked and
bolted, these could be leak points for the collector.
9.2.5
Installing the access components
When access components, such as an access platform, are ordered with the OptiFlo
RC, separate installation instructions will be provided with the collector.
9.2.6
Installation of control panel
Refer to the electrical drawings issued with the general arrangement drawing.
When the AAF Control Center or Pressure Demand controller is to be used, select a
location for fixing the enclosure within 15ft of the static taps located on either of the OptiFlo
RC side panels. Usually the Pressure Demand controller is fixed to the leg structure but it
can be remotely located if desired.
Once the pulse controller is fixed in position, connect two parallel lines of plastic
tubing to the 2 connection taps on the pulse controller and the other ends to the static taps
located on the side wall of the OptiFlo RC. These plastic pipes allow the pulse controller to
measure and display the differential pressure that exists between the clean air plenum and
dirty side plenum. In some modes of operation, this differential pressure is used to control
the pulsing.
Connect the high pressure port to the dirty side of the collector and connect the low
pressure port to the clean air side (back of the unit). Both ports are located on the side of
the collector.
See the separate pulse controller manual for a full explanation of its features and
modes of operation.
9.2.7
Installation of the cartridge filter elements
The cartridges supplied with new equipment are in most circumstances factory pre-
installed by AAF. If the cartridges have been shipped separately, or uninstalled, then
proceed as follows: