17
GDED-IOM-215-A
1. Provide safe access to the porthole doors at the front of the OptiFlo RC.
2. Open the filter access door by turning the knob counter clockwise until the door is
loose. Be sure to support the door during opening so it does not fall or drop and
become damaged.
3. Unpack and inspect new cartridges for any damage during shipping, storage or
handling. DO NOT use damaged cartridges.
4. Slide the new cartridges, gasket-end first, onto the support mandrels, two per
porthole (with exception of the 2RC4 and 3RC6). While installing, be careful that
cartridges do not contact the housing or any other objects which might damage or
puncture the cartridge surface.
5. Replace each door over filter. Tighten the knob in a clockwise direction until the
gaskets have sealed and compressed until air tight.
9.2.8
Installation of accessories
When accessories, such as sprinklers, abrasion resistant inlets, and airlocks, are
ordered with the OptiFlo RC, separate installation instructions will be provided with the
collector. For complete information, see the most current installation drawing or separate
IOM.
9.2.9
Electrical
connections
WARNING: Potential shock hazard. Disconnect power before servicing. Only
qualified electrical personnel should work on this system.
The OptiFlo RC pulse-jet cartridge collector is
supplied with electrical solenoids in a NEMA 4
enclosure and the standard pulse controller in a
NEMA4X enclosure. Higher NEMA ratings are available
as an option. Do not install in classified hazardous
locations without an enclosure suitably rated for the
application and location.
The standard pulse control supplied with the
OptiFlo RC is the DCT-1010 (or 1022) Dust Collector
Timer Controller. This pulse controller is used for on-
demand or continuous cleaning applications.