During filter element cleaning, a pulse controller automatically selects the element or
pair of elements to be cleaned, activating solenoid valves which open air diaphragm valves.
High pressure air pulses directly into the center of the selected element, or pair of elements,
for 100 milliseconds, blowing collected dust off the filter element(s). The dust is swept
downward into the hopper by the prevailing airflow and gravity.
3.4
Sizes
The OptiFlo RC pulse-jet cartridge collector is available in four
basic configurations: 2RC, 3RC, 4RC, and 5RC. All modules are two
filters elements wide and in every case, except for the 2RC4 and
3RC6, the filter elements are installed two cartridge elements deep –
two cartridges behind each circular access door.
The 2RC modules have filters arranged two high, 3RC modules
have filters arranged three high, 4RC modules have filters arranged
four high, and 5RC have filters arranged five high. The “RC” is
nomenclature for “Round Cartridge”. Each series offers standard
factory assembled collectors with model designations such as: 2RC8,
2RC16, 3RC12, 3RC24, 3RC46, 4RC16, 4RC32, 4RC48, 5RC20,
5RC40, 5RC80, and many others.
The second number is the designation of the total amount of
filters in the unit. Therefore, a 4RC64 would have filters arranged 4
high and have 64 total cartridges. Each door is two cartridges deep,
meaning there are 32 doors.
3.1
Filter elements
The OptiFlo RC utilizes cartridges with pleated media for dust
collection. For optimal performance, the OptiFlo RC is fitted with REDClean
®
N media as the standard cartridge. The REDClean N cartridge is suitable for
most applications where the OptiFlo RC is used. Contact AAF International for
assistance on a cartridge design for your application. To ensure proper
operation, it is recommended that you use only AAF International cartridges
on AAF International equipment.