Specifications
3
Caution:
*Relief valve has been factory fit with the water heater and set at 0.8 MPa
(8 Bar) rated pressure.
Warning:
Do not tamper or detach the safety valve from the water heater.
Dimensions
Model
A(mm)
A1(mm)
B(mm)
B1(mm)
C(mm)
HSE-HNS-050
850
376
434
195
427
HSE-HNS-060
717
305
483
230
483
HSE-HNS-080
876
405
483
230
483
Fig. 1
Model
HSE-HNS
HSE-HNS
HSE-HNS
-050
-060
-080
Rated volume [L]
50
60
80
Rated AC voltage [V]/Rated frequency [Hz]
~220/50
~220/50
~220/50
Rated input power
Quick power heating mode [W]
3000
3000
3000
Standard power heating mode [W]
3000/2000
3000/2000
3000/2000
Low power heating mode [W]
2000
2000
2000
Net weight [kg]
22
25
29
Reheating time for 35°C [3kW in min]
39
47
62
[2kW in min]
58
70
93
Temperature range [°C]
35-75
35-75
35-75
Rated water pressure
N/cm
80
80
80
Water head (metres)
80
80
80
Inlet/Outlet Connection [Inch]
BSP ½
BSP ½
BSP ½
2
B1
B
C
Hot water (outlet)
Cold water (inlet)
Relief valve*
A1
100
A
Quick
Standard
Heat
Modes
MAX
kWh
Hot Water
Quantity
Override
Energy
meter
Timer3
0
C
:
88 88
Timer 2
Timer 1
Timer 3
MAX
Low
Timer ON
Timer OFF
0
C
Clock/
Timers
Содержание HSE-HNS