background image

38

THIS WARRANTY IS APPLICABLE TO THE ORIGINAL 

OWNER ONLY in accordance with the warranty terms and 

conditions speci

fi

 ed below.

The warrantor will furnish the ORIGINAL OWNER,  1) a 

replacement water heater of equivalent size and current 

model if the glass-lined tank in this water heater leaks 

and,  2) a replacement part for any component part 

which fails. 
T H E   WAT E R   H E AT E R   R E P L A C E M E N T  M O D E L 

OR PART WILL BE WARRANTED FOR ONLY THE 

UNEXPIRED PORTION OF THE ORIGINAL WARRANTY.  

The warranty period will be determined by the original 

date of purchase of the water heater, or in the absence 

of a Bill of Sale verifying said date, from the date of 

manufacture indicated on rating plate affixed to this 

water heater.  This warranty is not transferable and 

applies to models listed below:

SERIES

TANK

PARTS

Conservationist

XGV, XGVL

10-Year

10-Year

ProMax 10-Year Models

XCV, XCVL, XCVH, XVR, 

XCVT, XCVX, XVRL

10-Year

6-Year

ProMax 6-Year Models

GCV, GCVL, GCVH, GVR, 

GCVT, GCVX, GCNH, GNR, 

GVRL

6-Year

6-Year

When the water heater has been used for other than single 

family residential application;  

1.  The  tank warranty shall be reduced to 1 year for 6 year

 

models and to 3 years for 10 year models.  

2.  The parts warranty shall be reduced to 1 year for all 

 models. 

CONDITIONS AND EXCEPTIONS

This warranty shall apply only when the water heater is 

installed and operated in accordance with 1) all local 

fi

 re 

codes and plumbing codes, ordinances and regulations, 

2) the printed instructions provided with it, 3) good industry 

practices, and 4) proper safety practices such as but not 

limited to a properly sized drain pan if installed in an area 

where leakage from the tank or its connections would result 

in damage to the area adjacent to the heater.  In addition, a 

new temperature and pressure relief valve, certi

fi

 ed by the 

Canadian Gas Association must have been properly installed 

and piped to the nearest drain.
This warranty shall apply only when the heater is:
•  owned by the original purchaser;
•  installed for indoor operation only;
•  used at temperatures not exceeding the maximum 

 

calibrated setting of its thermostat;

•  used at water pressure not exceeding the working 

 

pressure shown on the heater;

• 

fi

 lled with potable water, free to circulate at all times and 

 

with the tank free of damaging water sediment or scale 

 deposits;

•  used in a non-corrosive and non-contaminated 

 atmosphere;
•  used with factory approved anode(s) installed;
•  in its original installation location;
•  in the United States, its territories or possessions, and 

 Canada;
•  sized in accordance with proper sizing techniques for 

 

residential water heaters;

•  bearing a rating plate which has not been altered, defaced 

 

or removed except as required by the warrantor;

•  used in an open system or in a closed system with a 

 

properly sized and installed thermal expansion tank;

•  operated with properly installed drip leg in the gas supply 

 line;
• 

fi

 red with the fuel for which it was factory built;

• 

fi

 red at the factory rated input;

•  operated with the inner and outer combustion chamber 

  doors in place and all factory seals to combustion 
 chamber 

intact.

•  installed with no attempted, nor actual modi

fi

 cation  or

  alteration of the water heater’s design in any way,

   including but not limited to, the attachment of non-
 

company approved appliances or equipment.

Any accident to the water heater or any part thereof (including 

freezing, 

fi

 re, 

fl

 oods, or lightning), any misuse, abuse or 

alteration of it, any operation of it in a modi

fi

 ed form, any 

operation of the water heater on desalinated (deionized) 

water, or any damage caused by attempts to repair tank 

leaks or parts, will void this warranty.  This warranty does 

not cover water heaters replaced for cosmetic reasons or for 

reasons of noise, taste, odor, discolored and/or rusty water.  

This warranty does not apply to water heaters used to heat 

pools, whirlpools or hot tubs or used for space heating where 

its sizing does not conform with speci

fi

 cations of the heating 

component manufacturer.
This warranty gives you speci

fi

 c legal rights, and you may 

have other rights which vary under the laws of each state. If 

any provision of this warranty is prohibited or invalid under 

applicable state law, that provision shall be ineffective to the 
extent of the prohibition or invalidity without invalidating the 
remainder of the affected provision or the other provisions of 
this warranty.

SERVICE AND LABOR RESPONSIBILITY

UNDER THIS LIMITED WARRANTY, THE WARRANTOR 
WILL PROVIDE ONLY A REPLACEMENT WATER HEATER 
OR PART THEREOF. THE OWNER IS RESPONSIBLE FOR 
ALL OTHER COSTS. Such costs may include but are not 
limited to:
a.  Labor charges for service, removal, or reinstallation of 
 

the water heater or part thereof.

b.  Shipping and delivery charges for forwarding the new water 
 

heater or replacement part from the nearest distributor 

 

and returning the claimed defective heater or part to such 

 distributor. 
c.  All cost necessary or incidental for handling and 
  administrative charges, and for any materials and/or 
 

permits required for installation of the replacement heater 

 or 

part.

LIMITED RESIDENTIAL GAS WARRANTY

Содержание GAS WATER HEATER

Страница 1: ...h any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier ca...

Страница 2: ...Pipe Installation 17 Combination Space Heating Potable Water System 17 18 Solar Installation 18 Important Information About this Water Heater 19 Operating Your Water Heater 20 26 Lighting Instruction...

Страница 3: ...ty equivalent to a licensed tradesman in the fields of plumbing air supply venting and gas supply including a thorough understanding of the requirements of the National Fuel Gas Code as it relates to...

Страница 4: ...period of non use Read instruction manual before installing using or servicing water heater Fire or Explosion Harzard Hydrogen gas can be produced in a hot water system after a period of non use gener...

Страница 5: ...tat T Drain Valve U Manifold Burner Assembly V Flue W Metal Drain Pan X Piezo Igniter Y Base Ring Filter ALL PIPING MATERIALS TO BE SUPPLIED BY CUSTOMERS TO VENT TERMINATION ON ROOF A B D F G H I W V...

Страница 6: ...future users of this water heater will need it for future reference Service to the FVIR System should only be performed by a qualified technician Examples of a qualified technician include licensed pl...

Страница 7: ...the area of the water heater leave the area immediately and call the fire department from a neighbor s home Do not attempt to clean the spill until all ignition sources have been extinguished Fire or...

Страница 8: ...ice used in conjunction with a piped drain pan These devices are available from some plumbing supply wholesalers and retailers and detect and react to leakage in various ways Sensors mounted in the dr...

Страница 9: ...an L P gas supply Do not connect an L P gas water heater to a natural gas supply Failure to follow these instructions can result in death explosion or carbon monoxide poisoning Explosion Hazard Gas R...

Страница 10: ...in the occurrence of a leak in the system the gas will settle at floor level Basements crawl spaces closets and areas below ground level will serve as pockets for the accumulation of gas Before lighti...

Страница 11: ...y a qualified technician using the installation instructions Examples of a qualified technican include gas technicians authorized gas company personel and authorized service persons Failure to so do c...

Страница 12: ...typical examples of each method Louvers and Grilles In calculating free area for ventilation and combustion air supply openings consideration must be given to the blocking effect of protection louver...

Страница 13: ...y CSA International this certification applies to the vent damper device only and does not mean they are certified for use on this water heater U L recognized fuel gas and carbon monoxide CO detectors...

Страница 14: ...y is clear and free of obstructions The chimney must be cleaned if previously used for venting solid fuel appliances or fireplaces Also consult local and state codes for proper chimney sizing and appl...

Страница 15: ...losed System Thermal Expansion 5 Install a shut off valve in the cold water inlet line It should be located close to the water heater and be easily accessible Know the location of this valve and how t...

Страница 16: ...y cause excessive restriction to water flow is not recommended Use only 95 5 tin antimony or other equivalent solder Any lead based solder must not be used Piping that has been treated with chromates...

Страница 17: ...tions If this water heater is to be used to supply both space heating and domestic potable drinking water the instructions listed below must be followed Be sure to follow the manual s shipped with the...

Страница 18: ...water heating appliances when used to supply potable water Some jurisdictions may require a backflow preventer in the incoming cold water line This may cause the temperature and pressure relief valve...

Страница 19: ...t contain negative pressure producing devices such as exhaust fans fireplaces etc Is there a furnace air handler in the same room space as the water heater If so has a return air duct system been atta...

Страница 20: ...e outer door If the Pilot Does Not Light 1 Wait 10 minutes before another lighting attempt If the pilot does not light the Igniter may not be sparking or the unit may not be getting gas or for a new i...

Страница 21: ...hnician or your gas supplier DANGER Hotter water increases the risk of scald injury Consult the instruction manual before changing temperature Refer to the Lighting Instructions in the Installation Ma...

Страница 22: ...49 C 60 C is recommended by most dishwasher manufacturers The thermostat is adjusted to the pilot position when it is shipped from the factory Water temperature can be regulated by moving the temperat...

Страница 23: ...the heated water may vary Operating Modes and Settings Standard Mode The controller adjusts the water heater to maintain the temperature set by the user Vacation Setting The Vacation setting VAC sets...

Страница 24: ...ater conditioning company to successfully eliminate all water odor problems Artificially softened water is exceedingly corrosive because the process substitutes sodium ions for magnesium and calcium i...

Страница 25: ...water heater drain valve and allow all of the water to drain from the tank Flush the tank with water as needed to remove sediment 6 Close the drain valve refill the tank and restart the water heater...

Страница 26: ...d billed accordingly When ordering replacement parts always have the following information ready 1 model serial and product number 2 type of gas 3 item number 4 parts description See Repair Parts Sect...

Страница 27: ...ILOT THERMOPILE ASSEMBLY PILOT THERMOPILE ASSEMBLY IGNITER CONNECTOR THERMAL SWITCH CONNECTORS PILOT THERMOPILE THERMOPILE CONNECTOR WHITE WIRE RED WIRE PILOT TUBE NOT SHOWN FOR CLARITY FIGURE 26 7 Ro...

Страница 28: ...ort if glass is missing or damaged removed Replace door gasket if damaged Failure to follow these instructions can result in death explosion or fire 1 Check the door gasket for damage or imbedded debr...

Страница 29: ...Figure 19A 2 Turn off the gas at the manual shut off valve on the gas supply pipe Figure 3 3 Drain the water heater Refer to the section of Draining and Flushing and follow the procedure 4 Disconnect...

Страница 30: ...ostat temperature limit was ex ceeded Status light will blink 4 flashes 11 Pilot line or orifice clogged 12 Non functioning thermopile 13 Air for combustion obstructed 14 FVIR Flame Arrestor blocked w...

Страница 31: ...section 5 Clean filter See Cleaning the Combustion Chamber and Flame Arrestor section SMOKING AND CARBON FORMATION SOOTING 1 Insufficient combustion air 2 Low gas pressure 3 Water heater flue or vent...

Страница 32: ...on if the return air duct is in the same location Correct size of openings to allow sufficient air NO YES YES NO Section C Pilot light will not remain lit Complete this section after completing Sectio...

Страница 33: ...water heater has been operating but has stopped and will not re light check the flame arrestor for signs of high temperature blue or black discoloration indicating a flammable vapor incident If you s...

Страница 34: ...mostat 8 FLASHES This condition only appears if the gas control temperature knob has been turned off and the thermopile continued to produce electric power This condition can occur if the thermopile d...

Страница 35: ...35 NOTES...

Страница 36: ...1 DRAFT HOOD 2 HEAT TRAP COLD SOME MODELS 3 HEAT TRAP HOT SOME MODELS 4 COLD WATER DIP TUBE 5 ANODE ROD 6 TEMPERATURE PRESSURE RELIEF VALVE LOCATED TOP OR SIDE 7 DRAIN VALVE 8 GAS CONTROL VALVE THERM...

Страница 37: ...12B Burner L P Gas Item 13A Manifold Burner Assembly contains the door gasket manifold tube pilot thermopile assembly manifold component block thermal switch and burner Natural Gas Low Nox Item 13B M...

Страница 38: ...on location in the United States its territories or possessions and Canada sized in accordance with proper sizing techniques for residential water heaters bearing a rating plate which has not been alt...

Страница 39: ...M DOES NOT CONSTITUTE PROOF OF PURCHASE OR PROOF OF INSTALLATION DISCLAIMERS NO EXPRESSED WARRANTY HAS BEEN OR WILL BE MADE ON BEHALF OF THE WARRANTOR WITH RESPECT TO THE MERCHANTABILITY OF THE HEATER...

Страница 40: ...40 Copyright 2010 A O Smith Corporation All rights reserved...

Отзывы: