PAGE 68
23. APPENDIX B - FACTORY DEFAULT SETTINGS
SYSTEM
DEFAULT
OPTIONS
• Temperature Units
°F
°F / °C
• Negative Differential Alarm
Off
On / Off
•
Rate of Rise Start Up Delay [Min]
3
0 - 5
SPEED
DEFAULT
OPTIONS
•
Speed Monitoring
On
On / Off
• Scaling Units
%
PPM / RPM / USR / %
• Scaling Factor
12
User Defined
•
Speed detection Source
Dedicated
MAS / Dedicated / Differential
• Acceleration Monitoring Level
5
0 - 9
•
Number of Starts / Minute
3
1 - 10
•
Start Up Delay [S]
5
1 - 15
•
Underspeed Alarm [%]
10
1 - 10
•
Severe Underspeed [%]
20
1 - 20
•
Underspeed Alarm Delay [S]
1
0 - 10
•
Underspeed Stop Delay [S]
60
0 - 60
•
Overspeed [%]
10
1 - 10
•
Severe Overspeed [%]
20
1 - 20
•
Overspeed Alarm Delay [S]
1
0 - 10
•
Overspeed Stop delay [S]
60
0 - 60
ALIGNMENT (HEAD & TAIL)
DEFAULT
OPTIONS
• Sensor Pair
Contact
Off / Pulsed / Contact / Rub Block
• Trigger Alarm
Off
On / Off
•
Absolute Alarm [Deg]
140 °F
32 - 230 °F
• Relative alarm Source
Off
Off / AMB1 / AMB2 / Opposite
•
Relative Alarm [Deg]
30 °F
2 - 90 °F
•
Rate of Rise [Deg / Min]
3.0
0.5 - 5.0
•
Alarm Delay [S]
1
0 - 10
•
Stop Delay [S]
60
0 - 60
Some settings are dependent on others, so not all may be displayed or available to select.