PAGE 58
Back
OK
Image 36
Profile - Select New Profile
Leg (TS) / 1SP, 4BS, 4TS
Leg (RB) / 1SP, 4BS, 4RB
Leg (WDA) 4MA, 4BS
Leg (TS) / 1SP, 6BS, 6TS
14.12 SELECT NEW PROFILE -
MENU > SETUP (PASSWORD) > PROFILE > SELECT NEW PROFILE
To help make the setup process easier for bucket elevator legs, four preset program profiles are
available to choose from (Image 36). All four profiles are also listed in the WIRING DIAGRAMS section.
NOTE
All preset program profiles default to the factory settings. To modify settings from the factory defaults,
go to the EDIT SELECTED PROFILE menu.
14.11 RESTORE DEFAULTS -
MENU > SETUP (PASSWORD) > PROFILE > RESTORE DEFAULTS (PASSWORD)
All settings in the Watchdog can be restored to the factory default settings as described in Appendix B.
Before allowing the settings to be reset, the user is prompted to enter the engineering password again
and a final confirmation screen to confirm the action is displayed (Image 35). The menu choices are: X
(No) terminate without taking action, or OK (Yes), restore the factory defaults.
OK
Image 35
Profile - Restore Defaults
Over Write Existing
Settings?
X
1.
LEG (TS) / 1 SP, 4BS, 4TS
•
1 Speed Sensor
• 4 Bearing Temperature Sensors
•
4 Touchswitch Sensors (Alignment)
2.
LEG (RB) / 1SP, 4BS, 4RB
•
1 Speed Sensor
• 4 Bearing Temperature Sensors
•
4 Rub Block Sensors (Alignment)
3. LEG (WDA) 4MA, 4BS
• 4 Motion Alignment Sensors
• 4 Bearing Temperature Sensors
4. LEG (TS) / 1SP, 6BS, 6TS
•
1 Speed Sensor
• 6 Bearing Temperature Sensors
•
6 Touchswitch Sensors (Alignment)
Содержание Watchdog Super Elite