Chapter 2. CLI Syntax Reference
47
3ware SAS/SATA RAID Controller CLI Guide, Version 9.5.1
p4 OK u0 931.51 GB 1953525168 3QJ0392E
p5 OK u0 931.51 GB 1953525168 GTA000PAG67AGA
p6 DEGRADED u0 931.51 GB 1953525168 3QJ01PG6
p7 OK - 931.51 GB 1953525168 GTA000PAGE1RSA
p8 NOT-PRESENT - - - -
p9 NOT-PRESENT - - - -
p10 NOT-PRESENT - - - -
p11 NOT-PRESENT - - - -
p12 NOT-PRESENT - - - -
p13 NOT-PRESENT - - - -
p14 NOT-PRESENT - - - -
p15 NOT-PRESENT - - - -
Name OnlineState BBUReady Status Volt Temp Hours LastCapTest
---------------------------------------------------------------------------
bbu On Yes OK OK OK 0 xx-xxx-xxxx
/c
x
show alarms [reverse]
Asynchronous event notifications (also referred to as AENs or alarms) are
originated by firmware or SES attached enclosure (9690SA only) and
captured by their respective device drivers. These events reflect warnings,
debugging, errors, and/or informative messages for the end user. These events
are kept in a finite queue inside the kernel, awaiting extraction by user space
programs such as CLI and/or 3DM. They are also stored in the operating
system events log.
The
/c
x
show alarms
command displays all available alarms on a given
controller. The default is to display the alarms in ascending order—that is, the
oldest alarm messages appear at the top, and the most recent alarm or AEN
messages appear at the bottom. You can use the [
reverse
] attribute to display
the most recent alarm or AEN message at the top.
Alarms generated on 7000/8000 series controllers do not have dates, so you
will see a '-' in the Date column. This means that it is not applicable. In
addition, alarm messages on 7000/8000 controllers contain the severity in the
message text, so the Severity column also shows a '-'.
Example:
Typical output looks like:
//localhost> /c1 show alarms
Ctl Date Severity Alarm Message
---------------------------------------------------------------------------
c0 [Fri Mar 21 2008 14:19:00] WARNING Drive removed: port=1
c0 [Fri Mar 21 2008 14:19:00] ERROR Degraded unit: unit=1, port=1
c0 [Fri Mar 21 2008 14:19:25] INFO Drive inserted: port=1
c0 [Fri Mar 21 2008 14:19:25] INFO Unit operational: unit=1
c0 [Fri Mar 21 2008 14:28:18] INFO Migration started: unit=0
c0 [Sat Mar 22 2008 05:16:49] INFO Migration completed: unit=0
c0 [Tue Apr 01 2008 12:34:02] WARNING Drive removed: port=1
c0 [Tue Apr 01 2008 12:34:22] ERROR Unit inoperable: unit=1
c0 [Tue Apr 01 2008 12:34:23] INFO Drive inserted: port=1
c0 [Tue Apr 01 2008 12:34:23] INFO Unit operational: unit=1