![3Ware 720-0186-00 Скачать руководство пользователя страница 41](http://html1.mh-extra.com/html/3ware/720-0186-00/720-0186-00_manual_3239008041.webp)
Controller Object Commands
www.3ware.com
34
For controller models up to the 9650SE series, the
Port
summary section lists
all present ports and specifies the port number, disk status, unit affiliation, size
(in gigabytes) and blocks (512 bytes), and the serial number assigned by the
disk vendor.
For the 9690SA controller series, this section lists virtual ports, and specifies
the VPort number, disk status, unit affilication, drive type, phy number ( if
direct attached), the enclosure and slot (if expander attached), and model
number of the drive.
The
BBU
summary lists details about the BBU, if one is installed. It includes
a few important attributes such as hours left (in which the current BBU can
backup the controller cache in the event of power loss), temperature, voltage,
readiness, and so forth.
Additional attributes about controllers, units, ports and disks can be obtained
by querying for them explicitly. For details, see the other show subcommands.
Example output for 9650SE and earlier controllers:
//localhost> /c2 show
Unit UnitType Status %RCmpl %V/I/M Stripe Size(GB) Cache AVrfy
---------------------------------------------------------------------------
u0 RAID-5 OK - - 64K 596.004 ON OFF
u1 RAID-0 OK - - 64K 298.002 ON OFF
u2 SPARE OK - - - 149.042 - OFF
u3 RAID-1 OK - - - 149.001 ON OFF
Port Status Unit Size Blocks Serial
---------------------------------------------------------------
p0 OK u0 149.05 GB 312581808 WD-WCANM1771318
p1 OK u0 149.05 GB 312581808 WD-WCANM1757592
p2 OK u0 149.05 GB 312581808 WD-WCANM1782201
p3 OK u0 149.05 GB 312581808 WD-WCANM1753998
p4 OK u2 149.05 GB 312581808 WD-WCANM1766952
p5 OK u3 149.05 GB 312581808 WD-WCANM1882472
p6 OK u0 149.05 GB 312581808 WD-WCANM1883862
p7 OK u3 149.05 GB 312581808 WD-WCANM1778008
p8 OK - 149.05 GB 312581808 WD-WCANM1770998
p9 NOT-PRESENT - - - -
p10 OK u1 149.05 GB 312581808 WD-WCANM1869003
p11 OK u1 149.05 GB 312581808 WD-WCANM1762464
Name OnlineState BBUReady Status Volt Temp Hours LastCapTest
-------------------------------------------------------------------------
bbu On Yes OK OK OK 241 22-Jun-2004
The above output is for 9650SE and earlier controllers.
Note:
If an asterisk (*) appears next to the status of a unit, there is an error on one
of the drives in the unit. This feature provides a diagnostic capability for potential
problem drives. The error may not be a repeated error, and may be caused by an
ECC error, SMART failure, or a device error. Rescanning the controller will clear the
drive error status if the condition no longer exists
.