![3Ware 720-0186-00 Скачать руководство пользователя страница 51](http://html1.mh-extra.com/html/3ware/720-0186-00/720-0186-00_manual_3239008051.webp)
Controller Object Commands
www.3ware.com
44
/c
x
show numports
This command reports how many physical connections are made to the
controller and the total number of physical ports possible for the controller.
Example for a 9650SE-16ML with no drives attached:
//localhost> /c0 show numports
/c0 Number of Ports = 16
Example for 9690SA-8E with 8 dual-port SAS drives:
//localhost> /c3 show numports
/c3 Connections = 16 of 128
/c
x
show numunits
This command reports the number of units currently managed by the specified
controller /c
x
. This report does not include off-line units (or removed units).
Example:
//localhost> /c0 show numunits
/c0 Number of Units = 1
/c
x
show ondegrade
This feature only applies to 9500S controllers.
This command reports the cache policy for degraded units. If the ondegrade
policy is “Follow Unit Policy,” a unit cache policy stays the same when the
unit becomes degraded. If the ondegrade policy is off, a unit cache policy will
be forced to “off” when the unit becomes degraded.
Example:
//localhost> /c0 show ondegrade
/c0 Cache on Degraded Policy = Follow Unit Policy
/c
x
show pcb
This command reports the PCB (Printed Circuit Board) version of the
specified controller /c
x
.
Example:
//localhost> /c0 show pcb
/c0 PCB Version = RevX
/c
x
show pchip
This command reports the PCHIP (PCI Interface Chip) version of the
specified controller /c
x
.
Example:
//localhost> /c0 show pchip
/c0 PCHIP Version = 1.x