![3Ware 720-0186-00 Скачать руководство пользователя страница 123](http://html1.mh-extra.com/html/3ware/720-0186-00/720-0186-00_manual_3239008123.webp)
Enclosure Object and Element Commands
www.3ware.com
116
/cx/e
x
show fans
This command is used with the 9690SA controller. For the 9650SE and CCU
enclosure, simply drop the prepended controller name in the command and
use /e
x
.
This command lists the fans in enclosure
/cx/ex
and shows their status.
Example:
//localhost> /c0/e0 show fans
---Speed---
Fan Status State Step RPM Identify
------------------------------------------------------------
fan0 OK ON 1 2670 Off
fan1 OK ON 1 9370 Off
fan2 OK ON 1 8540 Off
fan3 OK ON 1 2810 Off
fan4 OK ON 1 9240 Off
fan5 OK ON 1 8330 Off
/c
x
/e
x
show temp
This command is used with the 9690SA controller. For the 9650SE and CCU
enclosure, simply drop the prepended controller name in the command and
use /e
x
.
This command lists the temperature sensors in enclosure
/cx/ex
and the
current temperature.
The maximum temperature for successful use of a drive should be noted in the
documentation for the drive.
Example:
//localhost> /c0/e0 show temp
TempSensor Status Temperature Identify
--------------------------------------------------------
temp0 OK 41C(105F) Off
temp1 OK 37C(98F) Off
temp2 OK 34C(93F) Off
temp3 OK 38C(100F) Off
temp4 OK 38C(100F) Off
temp5 OK 34C(93F) Off
temp6 NOT-INSTALLED - Off
temp7 NOT-INSTALLED - Off