User manual
47
www.3onedata.com
Operating method:
1. Use the configure method of
singe ring to configure 101, 102, 103, 104, 105 switch‟s port 5 and
port 6 as ring port and group is 1
2. Use the configure method of singe ring to configure 105, 106, 107, 108 switch‟s port 7 and port 8
as ring port and group is 2
3. Connect group 1 through network cable
4. Connect group 2 through network cable
5. Use BlueEyes software search the switches, the topology of the ring network.
105 switch belong to two different ring network group, so the network mark of ring network group must
different.
Coupling Configuration
Coupling ring structure figure as below:
Operating method:
1. Enable Ring Group 1 and Ring Group 2; (Hello_time can be disable too, if it enable, time of sending
Hello packet could not be very fast, or it will influence CPU dealing speed.);
2. Set up Port 1 and 2 of Device 105, 106 to be Ring Ports in Ring Group 1, Network ID is 1, Ring Type
Single; Set up Port 4 of device to be Coupling Port in Ring Group 2, Coupling Control Port is 2,
Network ID is 3, and Ring Type is Couple.
3. Set up Port 4 and 5 of Device 100, 101 to be Ring Ports in Ring Group 1, Network ID is 2, Ring Type
is Single; Set up Port 1 of device to be Coupling Port in Ring Group 2, Coupling Control Port is Port 4,
Network ID is 3, Ring type is Couple.
4. Set up Port 1 and 2 of Device 107, 108, 109 to be Ring Ports in Ring Group 1, Network ID is 1, Ring
Type is Single; Set up Port 4 and 5 of Device 102, 103, 104 to be Ring Port in Ring Group 1, Network