6
www.3onedata.com
2.7 LED Indicator
LED indictor light on the front panel of product, the function of each LED is described in the table as
below.
System indication LED
LED
State
Description
P1
ON
Power is being supplied to power input PWR1
OFF
Power is
not
being supplied to power input PWR1
P2
ON
Power is being supplied to power input PWR2
OFF
Power is
not
being supplied to power input PWR2
Alarm
ON
When the alarm is enabled, power or
the port‟s link is inactive.
OFF
Power and the port
‟s link is active, the alarm is disabled.
Run
ON/OFF System is not running well
Blinking
System is running well
Link/ACT
(1~12)
ON
Port connection is active
Blinking
Data transmitted
OFF
Port connection is not active
POE(1~8)
ON
The PoE device is connected by IEEE802.3af/at standard
OFF
No PoE power output or no PoE connected PoE devices
2.8 Installation
Before installation, confirm that the work environment meet the installation require, including the power
needs and abundant space. Whether it is close to the connection equipment and other equipments are
prepared or not.
1. Avoid in the sunshine, keep away from the heat fountainhead or the area where in intense EMI.
2. Examine the cables and plugs that installation requirements.
3. Examine whether the cables be seemly or not (less than 100m) according to reasonable scheme.
4. Power: support 48VDC power supply
5. Environment: working temperature: -40
~
70
℃
Storage Temperature: -40
~
85
℃
Relative humidity: 5%
~
95%