Managed Industrial Ethernet Switch User Manual
3onedata proprietary and confidential 64
Copyright © 3onedata Co., Ltd.
Interface Element
Description
in closed status; when alarm occurs, relay is in open
status;
⚫
Normally closed: when it's normal without alarm, relay is
in open status; when alarm occurs, relay is in closed
status.
Level state
Display the current status of power supply:
⚫
High level;
⚫
Low level.
External
Input
Alarm Settings
External Input Alarm Settings Column
Power
Display the device power supply number.
Alarm Setting
Configure the power supply alarm function. Options as
follows:
⚫
Enable;
⚫
Disable.
Status
Display current status of power supply:
⚫
Fault;
⚫
Normal.
Port Events
Port events column
Port
Display the device port number.
Alarm Setting
Configure the port alarm function. Options as follows:
⚫
Enable;
⚫
Disable.
Note
After enabling port alarm, when port is in abnormal status, such as
connection or disconnection, the device will output a signal to hint
the abnormal operation of device.
Connection
Display port connection status of the device:
⚫
Unconnected;
⚫
Connected.
Example: Alarm Configuration
For example: Enable alarm configuration, and enable power supply alarm for power 1,
port alarm for port 1.
Operation Steps
Log on to the Web configuration interface.