user can check the permission of used "community name" if the permission of "write" is
invalid.
Example: SNMP Configuration
(
B
)
For example: Enable SNMP configuration and configure the "Read-only community
name" as "public", "Read-write community name" as "private", "SNMP gateway" as
"192.168.1.1".
Operation Steps
Log on to the Web configuration interface.
Select "Main Menu > Remote Monitoring > SNMP Configuration".
On the displayed page of "SNMP Configuration":
1.
Select "enable" on the column of "SNMP Configuration";
2.
Select "Read-only community name" as "public";
3.
Select "Read/Write community name" as "private";
4.
Select "SNMP gateway" as "192.168.1.1".
Click "Apply".
End.
10.2
SNMP Configuration
Function Description
On the page of "SNMP Configuration", user can conduct the following operations:
⚫
Enable or disable SNMP configuration function;
⚫
Configure SNMP V1/V2 read-only community name;
⚫
Configure SNMP V1/V2 read-only community name;
⚫
Configure SNMP gateway.
Operation Path
Open in order: "Main Menu > Remote Monitoring > SNMP Configuration".
Interface Description
Interface screenshot of SNMP configuration as follows: