Main elements configuration description of serial port information interface: 

Interface Elements 

Description 

Obtain the Serial NO. 

Serial number configuration column 

Operation 

Pull-down list of serial port. 

Statistics information 

Statistics information column 

COM Send Error 

Quantity statistics of error bytes sent out by serial port. 

Channel Send Error 

Error bytes occur in channel or session 1-4. 

Link Information 

Link information column 

Link Information 

Display current work type, local port, target address, 

target port and other information of serial port. 

 

Содержание IEM615 Series

Страница 1: ...IEM615 SeriesManaged Industrial Ethernet Switch Module User Manual Version 02 Issue Date 2018 12 20 Industrial Ethernet Communication Solutions Expert 3onedata Co Ltd...

Страница 2: ...product service or features should be constrained by 3ondedata commercial contracts and clauses The whole or part product service or features described in this document may beyond purchasing or using...

Страница 3: ...aiwangxin High Technology Industrial Park Song Bai Road Nanshan District Shenzhen 518108 China Technology support tech support 3onedata com Service hotline 86 400 880 4496 E mail sales 3onedata com Fa...

Страница 4: ...suits for engineers as follows Network administrator responsible for network configuration and maintenance On site technical support and maintenance staff Hardware engineer Text Format Convention For...

Страница 5: ...e notes on the mark improper operation may cause personal injury Make a necessary supplementary instruction for operation description Configuration operation or tips for device usage Pay attention to...

Страница 6: ...L SERVER 7 3 1 COM SETTINGS 7 3 2 SERIAL PORT INFORMATION 11 4 CAN SERVER 13 4 1 CAN CONFIGURATION 13 4 2 CAN INFORMATION 17 5 PORT CONFIGURATION 19 5 1 PORT SETTING 19 5 2 BANDWIDTH MANAGEMENT 21 6 L...

Страница 7: ...56 9 1 LOGIN SETTINGS 56 10 REMOTE MONITORING 58 10 1 SNMP CONFIGURATION 58 10 2 SNMP CONFIGURATION 60 10 3 RELAY WARNING 63 11 PORT STATISTICS 66 11 1 FRAME STATISTICS 66 12 NETWORK DIAGNOSIS 71 12 1...

Страница 8: ...ystem should meet the following conditions Hardware and Software System Requirements CPU Above Pentium 586 Memory Above 128MB Resolution Above 1024x768 Color Above 256 color Browser Above Internet Exp...

Страница 9: ...tes While first configuring the switch if it is a local configuration mode please make sure that the network segment of current PC is 1 E g Assume that the IP address of the current PC is 192 168 5 60...

Страница 10: ...please strictly distinguish capital and small letter while entering Default username and password have the administrator privileges WebServer will provide 3 times opportunities to enter username and p...

Страница 11: ...Managed Industrial Ethernet Switch User Manual 3onedata proprietary and confidential 4 Copyright 3onedata Co Ltd After login in the device modify the switch IP address for usage convenience...

Страница 12: ...ht 3onedata Co Ltd 2System Configuration 2 1 System Information Function Description In System Information page user can check Device Information and Port Info Operation Path Open in order Main Menu S...

Страница 13: ...urrent using software version information updated software version has more functions MAC Address Hardware address of device factory configuration Contact Information Display the contact information o...

Страница 14: ...ngs Function Description On the page of COM Settings user can configure baud rate data bit stop bit parity bit and other basic parameters information of corresponding serial number and the operating m...

Страница 15: ...serial number selection Serial No Select corresponding serial number of the device Serial Parameter Settings Serial parameter settings column Baud Rate bps Select baud rate of corresponding serial nu...

Страница 16: ...l data to Ethernet data value range is 1 500ms COM Mode It s decided by software and hardware there are RS232 RS485 RS422 three modes Work Mode Settings Work Mode Settings Column Mode Setting Optional...

Страница 17: ...me of automatic disconnection and the serial server will break the session connection if there is no data transmission within given time If it s set to 0 the serial server won t positively break the c...

Страница 18: ...ress of address pool needs to be in the same network segment The start address value of address pool must be less than or equal to its end address value 3 2 Serial Port Information Operation Path Open...

Страница 19: ...Serial NO Serial number configuration column Operation Pull down list of serial port Statistics information Statistics information column COM Send Error Quantity statistics of error bytes sent out by...

Страница 20: ...the page of CAN Configuration user can configure the parameters information of corresponding CAN port such as session number TCP operating mode operating port baud rate operating mode of CAN server de...

Страница 21: ...CAN port number of the device CAN Parameters Settings Configuration column of CAN parameters Baud Rate Select the baud rate of corresponding CAN port number Options include 5K 10K 20K 30K 40K 50K 80K...

Страница 22: ...on between TCP client and server is established TCP Trubo Enabling TCP Turbo means that the number of subpackage frames is configured as 1 Work Mode Settings Configuration column of operating mode Mod...

Страница 23: ...rt of the device receives data AT 0 65535s the device sends out heartbeat packet after the setting time interval and the session will be disconnected if there is no reply for three consecutive times D...

Страница 24: ...art address of address pool can t be larger than the one of the end address of address pool 4 2 CAN Information Function Description On the page of CAN Information user can check and count the error i...

Страница 25: ...list and select the corresponding port number of CAN server Statistics Information Statistics Information Column CAN Send Error Count the error information transmitted by CAN server CAN BUS Error Coun...

Страница 26: ...can check port type rate and connection state set rate mode duplex mode port enable flow control and other parameters Speed duplex flow control will take effect when the port is enabled After selectin...

Страница 27: ...0M Half duplex 100M Auto Detect Notes All copper ports of the switch are MDI MDIX self adapting ports and support automated negotiation speed mode Duplex Click the drop down list box of Duplex to sele...

Страница 28: ...the ingress and egress bandwidth speed of the port Operation Path Open in order Main Menu Port Configuration Bandwidth Management Interface Description Bandwidth management interface as below The mai...

Страница 29: ...ion area click the option box of Enable In Egress area choose 4M as the egress speed of Port 1 In Ingress area choose 4M as the ingress speed of Port 1 Click Apply End Flow control should be enabled w...

Страница 30: ...wing benefits to users Limit the broadcast domain Increase the security of LAN Improve the network stability Flexiblely construct virtual working team Port VLAN Port VLAN adopts different identificati...

Страница 31: ...ity CFI Canonical Format Indicator represents whether MAC address is packaged in standard format in different transmission media 0 represents that MAC address is packaged in standard format VID VLAN I...

Страница 32: ...guration information Instance create port based VLAN The steps of configuring port based VLAN Open Main Menu L2 Feature VLAN On the option box of VLAN Mode select Port based VLAN Enter VLAN table item...

Страница 33: ...ame control Choose VLAN tag replace configuration options are No need change VID Replace VID into default VID Default VID The configuration bar of default VID 802 1Q VID VLAN ID number Its value range...

Страница 34: ...ut port 3 and Port 4 can t communicate with each other as the picture below Do not consider other ports how to set the VLAN Example Analysis Configure the Type of Port3 Port4 and Port5 as Access Port3...

Страница 35: ...ng entry analysis of Port 3 Port 4 and Port 5 forwarding entry design picture as follows Operation Steps Enter Main Menu Layer 2 Config VLAN Choose IEEE 802 1Q VLAN in the option box of VLAN mode Choo...

Страница 36: ...ber list Enter 5 in 802 1Q VID textbox In the drop down list of member type 1 Set the member type of Port3 to U 2 Set the member type of Port4 to U 3 Set the member type of Port5 to U Click Add edit b...

Страница 37: ...ace Interface Element Description IGMP snooping The switch of IGMP snooping function options are Enable Disable Notes IGMP snooping means snooping the messages between user host and router as well as...

Страница 38: ...list of static multicast Operation Path Open in order Main Menu L2 Feature Multicast Configuration Interface Description Static filtering interface as follows Main elements configuration description o...

Страница 39: ...or protocol please don t use them IGMP dynamic learning won t update statically typed multicast address static multicast forwarding table is more of a security mechanism Example Static Multicast Filte...

Страница 40: ...ht 3onedata Co Ltd 7QoS 7 1 QoS Classification Function Description On the page of QoS Classification user can set Queuing mechanism Enable ToS Enable CoS Port priority Operation Path Open in order Ma...

Страница 41: ...es and schedules in the decreasing order of priority When the queue with fairly high priority is empty then it would send groupings of queue with fairly low priority Port Port number of switch Inspect...

Страница 42: ...S values are the same queuing according to CoS priority Instance QoS configuration For example Set port 1 s queuing mechanism as Weight Fair 8 4 2 1 adopts ToS priority Operation steps Open Main Menu...

Страница 43: ...nding priority queue is Low When the CoS value is set to 2 and 3 the corresponding priority queue is Normal When the CoS value is set to 4 and 5 the corresponding priority queue is Medium When the CoS...

Страница 44: ...the CoS value is 6 choose High as the corresponding priority 8 When the CoS value is 7 choose High as the corresponding priority Click apply Ends 7 3 ToS Mapping Function Description On the page of C...

Страница 45: ...on For example When the ToS value is set to 0x00 0x3C the corresponding priority is Low When the ToS value is set to 0x40 0x7C the corresponding priority is Normal When the ToS value is set to 0x80 0x...

Страница 46: ...cription On the Rapid ring page user can choose redundancy protocol and configure the ring network under this protocol quickly Operation Path Open in order Main Menu Redundancy Rapid Ring Interface De...

Страница 47: ...sabled Ring V3 single ring coupling ring chain and Dual homing are supported RSTP IEEE 802 1W 1D rapid spanning tree Function description of Ring V1 V2 V3 On the rapid ring page user can choose Ring r...

Страница 48: ...on of two rings Type According to the requirement in the scene user can choose different ring network Single single ring using a continuous ring to connect all device together Couple couple ring is a...

Страница 49: ...Device 100 101 and 102 are port 1 and port 2 Therefore creating single ring is viable Port 1 and port 2 are set as the ring ports of each device Operation steps Configuring Device 100 101 and 102 in...

Страница 50: ...separately Note Port 1 and Port 2 cannot be set to the same port Click Apply Enter Main Menu System Management Device Address In the area of reboot the device click reboot End 8 1 2Instance create cou...

Страница 51: ...07 108 and 109 are in Ring 1 ring network ports are Port 1 and Port 2 single ring 105 is the master station others are slave stations 100 101 102 103 and 104 are in Ring 2 ring network ports are Port...

Страница 52: ...Click Apply Enter Main Menu System Management Device Address In the area of reboot the device click reboot End Operation Step 2 configuring Ring 2 in WEB interface Configuring Device 100 101 102 103...

Страница 53: ...vice Address In the area of reboot the device click reboot End Operation Step 3 configuring Ring 3 in WEB interface Configuring Device 100 101 105 and 106 in the following steps respectively Choose Ma...

Страница 54: ...tocol of Redundancy is Ring V3 Instance For example creating chain Its basic architecture is shown as below Instance analysis Basic framework we can make the following analyses 100 101 102 103 and 104...

Страница 55: ...nfiguring Device 100 101 102 and 103 in the following steps respectively Choose Main Menu Redundancy Rapid Ring In the Settings area of Rapid Ring page choose Ring V3 as Protocol of Redundancy Check t...

Страница 56: ...Ring In the Settings area of Rapid Ring page choose Ring V3 as Protocol of Redundancy Check the Enable box in the Group 1 In the Settings area of Rapid Ring page set the Type to Chain In the Settings...

Страница 57: ...at have already been set as ring network to Trunk and member relationship to Tagged When forming complicated ring networks like tangent ring please make sure the ID conforms to the unity of single rin...

Страница 58: ...the port of switch maintains in transition state listening and learning Note STP RSTP adopts a mechanism of state transition The newly selected root port and specified port have to go through twice t...

Страница 59: ...tion of RSTP status interface Interface Element Description Root information The display bar of root information table Local ID It displays the priority of this switch and MAC address information ID R...

Страница 60: ...cted switch port Edge The port that directly connects to terminal instead of other switches Connected It displays the network protocol of devices with connected ports Role Root port specified port Alt...

Страница 61: ...Trunking interface as follows The main element configuration description of static trunking interface Interface Element Description Enable Enable or disable trunking configuration Group Choose trunki...

Страница 62: ...runking On the page of Static Trunking check the box of Yes in the Enable bar Choose 1 in the droplist of Group Check the box of Port 1 and Port 2 in the join port bar Click Add Edit Click Apply End A...

Страница 63: ...Control 9 1 Login Settings Function Description On the Login Settings page user can configure the login name and password of logging in to WEB configuration page and other parameter information Opera...

Страница 64: ...configuration interface Note The password should a combination of letters that less than 16 bytes Confirm password Confirm password Please keep the modified login name and password in mind If you forg...

Страница 65: ...he page of SNMP Configuration user can conduct the following operations Enable or disable SNMP configuration function Configure SNMP V1 V2 read only community name Configure SNMP V1 V2 read only commu...

Страница 66: ...an be used widely but exists security issue SNMP V2 Semantics has been enhanced and it supports TCP protocol SNMP Read Community Configure the read only SNMP community name with the only operation per...

Страница 67: ...Configuration On the displayed page of SNMP Configuration 1 Select enable on the column of SNMP Configuration 2 Select Read only community name as public 3 Select Read Write community name as private...

Страница 68: ...nction options as follows Enable Disable SNMP V1 V2 SNMP supports the following version SNMP V1 It adopts UDP protocol which can be used widely but exists security issue SNMP V2 Semantics has been enh...

Страница 69: ...ng cold or warm start port offline online power on off Please pay attention to the permission problem of read and write in the SNMP browser user can check the permission of used community name if the...

Страница 70: ...strator and quickly repair the equipment status to avoid excessive losses Operation Path Open in order Main Menu Remote Monitoring Relay Warning Interface Description Relay warning interface as follow...

Страница 71: ...onfigure the power supply alarm function Options as follows Enable Disable Status Display current status of power supply Fault Normal Port Events Port events column Port Display the device port number...

Страница 72: ...in Menu Remote Monitoring Relay Warning On the displayed page of Relay Warning 1 Select enable on the column of Alarm Setting 2 Select Relay Output Type as open On the region of System Events select E...

Страница 73: ...stics 11 1 Frame Statistics Function Description On the page of Frame Statistics user can check frame statistics of sending receiving data packets transmitted by the port within a period of time Opera...

Страница 74: ...ansmitted by a port excluding preamble but including FCS TxDropPkts This counter is incremented every time a transmit packet is dropped due to lack of resources TxBroadcastPkts The number of good pack...

Страница 75: ...the medium is busy This only applies to the Half Duplex mode while the Carrier Sensor Busy TxLateCollision The number of times that a collision is detected later than 512 bit times into the transmiss...

Страница 76: ...ize inclusive RxOversizePkts The number of good packets received by a port that are greater than 1522 bytes tagged and 1518 bytes untagged RxJabbers The number of packets received by a port that are l...

Страница 77: ...rror or an alignment error JumboPkt The number of good packets received by a port that are greater than the standard maximum size and less than or equal to the jumbo packet size regardless of CRC or a...

Страница 78: ...1 Port Mirror Function Description On the Port Mirror page user can enable or configure the correspondence between ingress data mirror and egress data mirror Operation Path Open in order Main Menu Di...

Страница 79: ...ingress egress data mirroring Watch direction Backup data during mirroring options are All Ingress Egress For instance port mirror configuration For example use port 4 to collect ingress data and egre...

Страница 80: ...dress Function Description On the page of Network Settings user can conduct following operations Configure default IP address of the device Configure netmask Configure gateway address Configure DNS se...

Страница 81: ...ce IP address IP Address Configure IP address of the device Notes Default configured IP address is 192 168 1 254 Subnet Mask Configure subnet mask of the device Notes Default configured subnet mask is...

Страница 82: ...eboot Step 3 On the Network Settings region of displayed page of Device Management select Use the following IP address a Enter 192 168 5 88 in the textbox of IP Address b Enter 192 168 5 1 in the text...

Страница 83: ...f system information interface Interface Elements Description Module Configure the device model Name Configure the device name to identify each device in the network Description Configure the device s...

Страница 84: ...interface Step 2 Select Main Menu Basic Settings System Identification Step 3 On the Settings region of displayed page of System Identification a Enter Module as ManagedSwitch1 b Enter Name as Indust...

Страница 85: ...status to be in the factory status default IP address is 192 168 1 254 Update Configuration File from Local PC Configuration column of configuration files Download Configuration Download the configur...

Страница 86: ...Management click Download Click Save S on the pop up dialog box of File Download Select save path on the pop up dialog box of Save as Click Apply End Example Upload Configuration For example Upload c...

Страница 87: ...rrent user For example Log off and change administrator to login For example Log off current user and then login again via entering admin8 in the column of administrator and admin8 in the column of pa...

Страница 88: ...forgetting the login password the password can be initialized by restoring factory setting specific method is adopt BlueEyes_ software to search and use restore factory setting function to initialize...

Страница 89: ...ch port faults User can locate the faults via following tests Connected computer and switch ports keep invariant change other network cable Connected network cable and switch port keep invariant chang...

Страница 90: ...eshooting connect the network cable again Ethernet terminal device or network card works abnormally troubleshooting eliminate the terminal device fault Not connected to the power socket troubleshootin...

Страница 91: ...line or shields the interference source Site wiring is not normative Troubleshooting optical fiber network cable optical cable cannot be arranged with power line and high voltage line Network cable i...

Страница 92: ...ata Co Ltd 3onedata Co Ltd Headquarter address 3 B Zone 1 Baiwangxin High Technology Industrial Park Song Bai Road Nanshan District Shenzhen Technology support tech support 3onedata com Service hotlin...