Interface Element Description
(bytes)
range, data frame that is greater or equal to given frame
length should be forwarded; value range is 1-1460bytes.
Data Bits (bits)
Select data bits of corresponding serial number. Options
include:
⚫
5 bits;
⚫
6 bits;
⚫
7 bits;
⚫
8 bits.
Stop Bits (bits)
Select stop bits of corresponding serial number. Options
include:
⚫
1 bits;
⚫
1.5bits;
⚫
2 bits.
Notes:
⚫
When the data bit is 5 bits, stop bit options include "1 bits" and
"1.5 bits";
⚫
When the data bit is 6/7/8 bits, stop bit options include "1 bits"
and "2 bits".
Character delay
Interval time of serial data to Ethernet data, value range is
1-500ms.
COM Mode
It's decided by software and hardware, there are RS232,
RS485, RS422 three modes.
Work Mode
Settings
Work Mode Settings Column
Mode Setting
Optional modes of the device as follows:
⚫
Basic: TCP Client, TCP Server, UDP, TcpAuto;
⚫
Advanced: TCP Server, UDP.
Sessions
1-4, each serial port of serial server supports 1-4 sessions.
Session refers to the process serial server transmits data
received from serial port to Ethernet via socket connection.
Local Port
1-65535, it refers to TCP port that is provided by serial server
and can be connected by other TCP/IP nodes. The port is
connected to relative serial ports of serial server. System will
automatically distribute local port number when it's "0", fixed
local port number will be used when it's not "0".
Target Address
IP address or domain name address to be connected to serial