
3D Systems, Inc.
18
p/n 76-D022 Rev. A
SLS SINGLE MQC SYSTEM POWER REQUIREMENTS
COMPONENT
REQUIREMENTS
Input voltage (Single Phase)
208-230VAC, 50/60Hz, 1PH
Normal operating current
1 .6 A
Peak operating current
4A
On/Off breaker rating
5A
Power Cable IEC320-C19 Plug
16AWG (ø1 .29mm)
(2 Cond P .E . Connection)
Maximum Room Ambient Temperature
27 °C
GROUNDING REQUIREMENTS
All connections between powered equipment and the power panel must be grounded as shown in the diagram below .
< 5 Ω
< 5 Ω
< 5 Ω
< 5 Ω
< 5 Ω
< 5 Ω
< 5 Ω
< 5 Ω
ProX 500
SLS System
MQC
Non-Igniton
Vacuum
Bead
Blaster
Main
Power Panel
Power
Subpanels
Frame Ground