89
3D SYSTEMS, INC
.
PN:80-D27 Rev.B
Silicon scraper replacement
The two silicon scrapers must be replaced every 6 months . They are located at the left and right corners of the
manufacturing chamber .
Part Number:
•
Silicon scraper : 5006328W00_B (quantity needed: 2)
Caution: Personal Protective Equipment (PPE) must be used to protect the user against health or
safety risks during working tasks . Wear disposable rubber gloves, anti-static coverall, anti-static safety
shoes and safety glass . Wear disposable dust mask rated FFP3 or N99 level protection at minimum ; we
recommand the use of powered air purifying respirator .
Procedure:
1 . Clean the manufacturing chamber as explained on the section "Cleaning the manufacturing chamber" on page 65 .
This step must be performed carrefully as the maintenance will require to access the manufacturing chamber .
2 . Move the carriage to position 300mm .
3 . Switch off the printer (see section "Shutting printer down" on page 66) .
4 . Switch the locking key to position ”O”, remove the key and keep it with you . This will prevent any power up of the
printer during the maintenance .
5 . Release the 8 screws of the front door of the main cabinet by using a 13mm socket wrench .
6 . Open the left panel of the main cabinet, and connect the crank
handle on the door-opening system .
Left silicon scraper
Right silicon scraper
Crank handle fitting
Crank handle