49
3D SYSTEMS, INC
.
PN:80-D27 Rev.B
3
Information area
•
ATMOSPHERE
•
Gas
(mode of the gas supplied): REGUL (regulation around an oxygen target value), DIRECT (continuous injection of
gas at a constant rate), OFF (no gas injection),
•
Status of the gas valve indicator : if green, the valve is opened,
•
O2 value
: current oxygen level value in PPM (particles per million) on the manufacturing chamber,
•
O2 setpoint
: oxygen level target value,
•
Enclosure pressure
: current pressure value on the manufacturing chamber,
•
Enclosure temperature
: current temperature value on the manufacturing chamber .
•
LENS CLEANER
•
Turbine
: state of the lens cleaner blower (turbine) . If green/white, the blower is operating/not operating,
•
Setpoint
: setpoint of the blower operating, in %,
•
Differential pressure
: [Outlet Pressure – Inlet Pressure] of the external filter.
•
PART
•
Clamping
: status of the base plate clamp . If green/white, clamping is ON/OFF,
•
Available powder
: the height of the powder available in the feeding piston in mm,
•
Zero sintering
: the zero position of the sintering piston in mm .
•
LASER/OPTIC
•
Defocus
: defocusing value in mm,
•
Laser power
: current Laser power, in % .