3D Systems, Inc.
POST-PROCESSING BUILD PARTS
Due to the large size of the ProX 950 build platform and the potentially large size of 3D builds, it is highly recommended to have
a two-RAMCO system for part cleaning, one filled with TPM (Tripropylene Glycol Methyl Ether) and the other filled with water. A
RAMCO is machine that agitates 3D parts in different liquids to remove uncured resin. This procedure assumes you have already
let build parts drain over the MDM and have used the offload cart to move the print platform to your post-processing area.
WHEN WORKING WITH GREEN MATERIAL (THAT WHICH IS NOT FULLY CURED) IT IS IMPORTANT TO WEAR
PROTECTIVE EQUIPMENT SUCH AS SAFEFTY GLASSES, FACE SHIELDS, GLOVES, AND LAB COATS . IT IS ALSO
NECESSARY TO USE THE PROPER METHODS OF DISPOSAL OF 3D-PRINT WASTE MATERIAL .
1. Wearing nitrile gloves, and with the help of another person, move the build platform into the TPM RAMCO and secure it to the
RAMCO’s platform.
NOTE: Do not simply remove the parts from the build platform without first removing the platform from the
machine . Doing so could cause build debris to end up in the MDM and damage future builds .
16
2. Flip the top switch (1) on the left side of the RAMCO down to lower the platform down into the TPM.
3. Turn the knob (2) on the right side of the RAMCO to close the lid. Press the green
start
button (3) to start the machine. Allow
the system to clean the parts for up to 40 minutes.
4. Lean build platform at a slant against the back of the RAMCO
to allow excess TPM to drain from the parts and platform.
5. When the platform stopps dripping, and with the help of
another person, move the build platform into the water
RAMCO to further strip the parts of resin. Secure the build
platform to the RAMCO platform and perform Steps 2 through
4 once more.
NOTE: Although these directions state to bathe the
parts in the RAMCOs for 40 minutes each, you may
have to leave them in a longer or shorter time to clean
the parts of resin . Solubility and concentration of the
resin in TPM and water will dictate sufficient bathing
time .
Build parts have been blurred for privacy.
1
2
3
Build parts have been blurred for privacy.
50