3D Systems, Inc.
Inspect Planarizer Blade Routine
If any of these signs are visible on the Planarizer Blade it will need to be replaced:
•
Excess buildup that cannot be cleaned off
•
Blade is warped
•
Blade is damaged (bent or kinked)
To change planarizer blade:
1 . Move print engine to the
Ready
state . This will place the
printer over build plate area and will tilt the blade .
2 . Lift the cover to expose the planarizer blade .
3 . Loosen 2x5 cap screw holding planarizer blade in place with
a 1 .5mm Allen wrench .
4 . Carefully pull blade out of aluminum housing .
CAUTION: Blade is sharp, be careful not to cut
yourself when removing blade .