V7122 GatewayUser Guide
Function Specification
Rear Panel
Trunks
1 to 8 and 9 to 16
Two 50-pin female Telco connectors (DDK57AE-40500-21D) or 8 RJ-48c
connectors for trunks 1 to 8 only
Ethernet 1 and 2
Two 10/100 Base-TX, RJ-45 shielded connectors
RS-232
Console port - DB-9
AC Power
Standard IEC320 Appliance inlet.
Option for a dual (fully redundant) power supply.
2-pin terminal block (screw connection type) suitable for field wiring
applications connecting DC Power connector: MSTB2.5/2-STF (5.08 mm)
from Phoenix Contact.
Bonding and earthing: A 6-32-UNC screw is provided. Correct ring terminal
and 16 AWG wire minimum must be used for connection.
Or crimp connection shown below.
DC Power
Note that to meet UL approvals, users must fulfill the criteria
below.
2-pin terminal block (crimp connection type) comprising a
Phoenix Contact Adaptor:
Shroud:
MSTBC2,5/2-STZF-5,08.
Contacts: MSTBC-MT0,5-1,0
Cable requirement:
18 AWG x 1.5 m length.
Physical
AC Power Supply
Universal 90 to 260 VAC 1A max, 47-63 Hz
Option for a dual redundant power supply.
AC Power Consumption
1 or 2 span: 39.7 W
4 spans: 42.1 W (approximated)
8 spans: 45.3 W
DC Power Supply
(optional)
36 to 72 VDC (nominal 48 VDC), 4A max, floating input
DC Power Consumption
1 or 2 span: 28.8 W
4 spans: 32.8 W
8 spans: 36.4 W
Environmental (DC)
Operation Temp:
0° to 40° C / 32° to 104° F
Short Term Operation Temp (per NEBS):
0° to 55° C / 32° to 131° F
Storage:
-40° to 70° C / -40° to 158° F
Humidity: 10
to
90%
non-condensing
Environmental (AC)
Operation Temp: 0° to 40° C / 32° to 104° F
Storage: -40° to 70° C / -40° to 158° F
Humidity:
10 to 90% non-condensing
Hot Swap
cPCI cards are full hot swap supported
Power supplies are redundant but not hot swappable
Содержание VCX V7122
Страница 28: ...28 V7122 GatewayUser Guide ...
Страница 39: ...V7122 Gateway User Guide 39 Reader s Notes ...
Страница 40: ...40 V7122 GatewayUser Guide ...
Страница 58: ...58 V7122 GatewayUser Guide Reader s Notes ...
Страница 66: ...66 V7122 GatewayUser Guide Reader s Notes ...
Страница 144: ...144 V7122 GatewayUser Guide Reader s Notes ...
Страница 239: ...V7122 Gateway User Guide 239 Reader s Notes ...
Страница 240: ...240 V7122 GatewayUser Guide ...
Страница 246: ...246 V7122 GatewayUser Guide Reader s Notes ...
Страница 270: ...270 V7122 GatewayUser Guide Reader s Notes ...
Страница 287: ...V7122 Gateway User Guide 287 Reader s Notes ...
Страница 288: ...288 V7122 GatewayUser Guide ...
Страница 294: ...294 V7122 GatewayUser Guide Reader s Notes ...
Страница 300: ...300 V7122 GatewayUser Guide Figure 88 Gateway s Startup Process ...
Страница 315: ...V7122 Gateway User Guide 315 Reader s Notes ...
Страница 316: ...316 V7122 GatewayUser Guide ...
Страница 332: ...332 V7122 GatewayUser Guide Reader s Notes ...
Страница 358: ...358 V7122 GatewayUser Guide Reader s Notes ...
Страница 362: ...362 V7122 GatewayUser Guide Reader s Notes ...
Страница 389: ...V7122 Gateway User Guide 389 Reader s Notes ...
Страница 390: ...390 V7122 GatewayUser Guide ...
Страница 398: ...398 V7122 GatewayUser Guide Reader s Notes ...
Страница 406: ...406 V7122 GatewayUser Guide Reader s Notes ...
Страница 408: ...408 V7122 GatewayUser Guide Reader s Notes ...
Страница 409: ...V7122 Gateway User Guide 409 ...
Страница 419: ...V7122 Gateway User Guide 419 Reader s Notes ...
Страница 437: ...V7122 Gateway User Guide 437 Reader s Notes ...
Страница 452: ...452 V7122 GatewayUser Guide Figure 137 UDP2File Utility ...
Страница 453: ...V7122 Gateway User Guide 453 Reader s Notes ...
Страница 459: ...V7122 Gateway User Guide 459 Reader s Notes ...
Страница 475: ...V7122 Gateway User Guide 475 ...