Installation Manual
H3C S7500 Series Ethernet Switches
Chapter 2 Line Processing Units
2-49
(1) 10GBase-XFP port number
(2) 10GBase-XFP port status LED (LINK)
(3) 10GBase-XFP port status LED (ACT)
(4) Silkscreen of the LPU name
(5) Captive screw
(6) LPU edge (green)
(7) Ejector lever
(8) 10GBase-XFP port
Figure 2-63
Partially amplified view of the LS81TGX2 panel
The following table describes the LEDs of the LS81TGX2:
Table 2-44
LED description of the LS81TGX2
LED
State
OFF
No link is present.
LINK
ON
A link is present.
OFF
No data is being transmitted/received.
ACT
Blinking
Data is being transmitted/received.
2.22.3 Matching Cable
Table 2-45
Cables for the LS81TGX2
XFP module
Central
wavelength
Connector
Matching
cable
Maximum
transmissio
n distance
XFP-SX-MM850 850
nm
50 µm/125 µm
multi-mode
optical fiber
300 m (984.3
ft)
XFP-LX-SM1310 1,310
nm
10 km (6.2
mi)
XFP-LH40-SM15
50
1510 nm
40 km (24.9
mi)
XFP-LH80-SM15
50
1510 nm
LC
9 µm/125 µm
single-mode
optical fiber
80 km (49.7
mi)