By default, log entries that are assigned a critical or warning level
remain in the log after a switch reboot. Issuing a clear log command
does not remove these static entries. To remove log entries of all levels
(including warning or critical), use the following command:
clear log static
■
Subsystem
— The subsystem refers to the specific functional area to
which the error refers.
Table 33
describes the subsystems.
■
Message
— The message contains the log information with text that
is specific to the problem.
Local Logging
The switch maintains 1,000 messages in its internal log. You can display a
snapshot of the log at any time by using the command
show log {<priority>}
where the following is true:
■
priority
— Filters the log to display message with the selected
priority or higher (more critical). Priorities include (in order) critical,
emergency, alert, error, warning, notice, info, and debug. If not
specified, informational priority messages and higher are displayed.
Table 32
Fault Levels Assigned by the Switch
Level
Description
Critical
A desired switch function is inoperable. The switch may need to be reset.
Warning
A noncritical error that may lead to a function failure.
Informational
Actions and events that are consistent with expected behavior.
Table 33
Fault Log Subsystems
Subsystem
Description
Syst
General system-related information. Examples include memory, power supply, security
violations, fan failure, overheat condition, and configuration mode.
STP
STP information. Examples include an STP state change.
Brdg
Bridge-related functionality. Examples include low table space and queue overflow.
SNMP
SNMP information. Examples include community string violations.
Telnet
Information related to Telnet login and configuration performed by way of a Telnet session.
VLAN
VLAN-related configuration information.
Port
Port management-related configuration. Examples include port statistics and errors.
Содержание 3C17705
Страница 1: ... http www 3com com SuperStack II Switch 9100 User Guide Part No DUA1770 5AAA01 Published January 2000 ...
Страница 10: ...GLOSSARY INDEX INDEX OF COMMANDS 3COM CORPORATION LIMITED WARRANTY EMC STATEMENTS ...
Страница 14: ...14 ABOUT THIS GUIDE ...
Страница 32: ...32 CHAPTER 2 INSTALLATION AND SETUP ...
Страница 62: ...62 CHAPTER 3 ACCESSING THE SWITCH ...
Страница 80: ...80 CHAPTER 4 VIRTUAL LANS VLANS ...
Страница 86: ...86 CHAPTER 5 FORWARDING DATABASE FDB ...
Страница 98: ...98 CHAPTER 6 SPANNING TREE PROTOCOL STP ...
Страница 110: ...110 CHAPTER 7 QUALITY OF SERVICE QOS ...
Страница 124: ...124 CHAPTER 8 STATUS MONITORING AND STATISTICS ...
Страница 130: ...130 CHAPTER 9 USING THE WEB INTERFACE ...
Страница 136: ...136 CHAPTER 10 SOFTWARE UPGRADE AND BOOT OPTIONS ...
Страница 156: ...156 APPENDIX C TROUBLESHOOTING ...
Страница 162: ......
Страница 176: ...176 INDEX ...
Страница 180: ...180 INDEX OF COMMANDS ...