48
2N TELEKOMUNIKACE a.s., www.2n.cz
®
Enter the command to set the maximum accumulator voltage in mV.
at^scchg="max_current",350
Enter the command to set maximum charging current in mA.
at^scchg="state"
Enter the command to know the current charging state.
ACTIVE- charging activated.
STOPPED- charging stopped.
at^scchg="start"
Enter the command to enable the charging function.
at^scchg="stop"
Enter the command to disable the charging function.
at^scchg="save"
Enter the command to save the currently made changes.
at^scchg="srestart"
Enter the command to save the changes and modify the charging parameters
immediately.
at^scchg?
Enter the command to display the current charger settings and charging state.
at^scchg=?
Enter the command to display the charger setting options
.
Warning
Remember to set the charger parameters before connecting the
accumulator and starting the charging process. Make sure that the
settings are in compliance with the accumulator manufacturer's
catalogue values to avoid accumulator damage, fire or explosion.
Caution
Use a 6V or 12V gel-lead-acid accumulator only for charging. Make
sure that the charging voltage is at least 1V higher than the maximum
voltage of the accumulator connected.