39
2N TELEKOMUNIKACE a.s., www.2n.cz
®
Enter the command to make automatic port calibration according to the currently
measured value.
at^scadc2="threshold_low",300
Manual calibration setting (minimum values). Setting options: 0 – 960.
at^scadc2="threshold_high",350
Manual calibration setting (maximum values). Setting options: 0 – 960.
at^scadc2="save"
Enter the command to save the changes.
at^scadc2?
Enter the command to display the currently set port values.
at^scadc2=?
Enter the command to display the port setting options.
at^scdin1="get_value"
Enter the command to detect the logical level on the port and send value 1/0.
at^scdin1="calib_min"
Enter the command to make automatic port calibration according to the currently
measured value.
at^scdin1="calib_max"
Enter the command to make automatic port calibration according to the currently
measured value.
at^scdin1="threshold_low",400
Manual calibration setting (minimum values). Setting options: 0 – 960.
at^scdin1="threshold_high",450
Manual calibration setting (maximum values). Setting options: 0 – 960.
at^scdin1="save"
Enter the command to save the changes.
at^scdin1?
Enter the command to display the currently set port values.
at^scdin1=?
Содержание SmartCom
Страница 1: ...www 2n cz Firmware Version 2N SmartCom Wireless Device Management over IP User Manual 1 8 0 1 8 x ...
Страница 72: ...72 2N TELEKOMUNIKACE a s www 2n cz Figure IP Access Menu ...
Страница 135: ...135 2N TELEKOMUNIKACE a s www 2n cz Others Dimensions w o connectors 105 x 100 x 30 mm CE certificate ...