108
2N TELEKOMUNIKACE a.s., www.2n.cz
®
Note
Therefore, to read data from terminal No. 50–0295–0562, enter one
of the following commands into API:
ATD5002950562#100.
When you receive the CONNECT reply, the following commands will
become available.
at^scwmbus="get_oldest"
Enter the command to write out the oldest record from the Wireless M–Bus meter
data space. Example of reply:
^SCWMBUS: <timestamp>,<id>,<rssi>,<len>,"<binary data in hexadecimal format>"
Meaning of parameters:
timestamp – record receiving time (UNIX timestamp)
id – record code in circular buffer
rssi – signal intensity in dBm during message receiving
len – received message length in bytes
at^scwmbus="del_oldest"
Enter the command to delete the oldest record from the Wireless M–Bus meter
data space. Delete the oldest record and enter the 'get_oldest' command to read
the oldest but one record.
at^scwmbus="del_all"
Enter the command to delete all records from the Wireless M–Bus meter data
space
.
Firmware Management
Enter the command to control and set terminal upgrades.
at^scupg<ser_no>?
The current upgrade state reply is received.
at^scupg<ser_no>="<version>"[,<timestamp>]
The FW version and timestamp are set for the terminal upgrade.
Содержание SmartCom
Страница 1: ...www 2n cz Firmware Version 2N SmartCom Wireless Device Management over IP User Manual 1 8 0 1 8 x ...
Страница 72: ...72 2N TELEKOMUNIKACE a s www 2n cz Figure IP Access Menu ...
Страница 135: ...135 2N TELEKOMUNIKACE a s www 2n cz Others Dimensions w o connectors 105 x 100 x 30 mm CE certificate ...