Enter the command to save the changes and restart the interface.
at^scport1?
Enter the command to display the currently set port values.
at^scport1=?
Enter the command to display the port setting options.
^SCPORT1: "BAUDRATE",110-230400
^SCPORT1: "DATA_BITS",5-8
^SCPORT1: "STOP_BITS",1-2
^SCPORT1: "PARITY",0-4
^SCPORT1: "FLOWCONTROL",0-1
^SCPORT1: "SAVE"
^SCPORT1: "RESTART"
^SCPORT1: "SRESTART"
Port 2 (RS 485/M-Bus) SC Commands
These commands are used for setting the RS 485/M-Bus parameters.
at^scport2="baudrate",9600
Enter the command to set the baud rate to 9,600 bps.
at^scport2="baudrate",115200
Enter the command to set the baud rate to 115,200 bps.
at^scport2="baudrate",230400
Enter the command to set the baud rate to 230,400 bps.
The baud rate can be set to 110 – 230,400 in standard steps.
at^scport2="data_bits",8
Enter the command to set the data bits to 8. Setting options: 5-8.
at^scport2="stop_bits",2
Enter the command to set the stop bits to 2. Setting options: 1-2.
at^scport2="parity",2
Enter the command to set the parity check type. Setting options: 0-4.
at^scport2="save"
Enter the command to save the changes.
at^scport2="restart"
Содержание SmartCom