40
2N TELEKOMUNIKACE a.s., www.2n.cz
®
Enter the command to display the port setting options.
at^scdin2="get_value"
Enter the command to detect the logical level on the port and send value 1/0.
at^scdin2="calib_min"
Enter the command to make automatic port calibration according to the currently
measured value.
at^scdin2="calib_max"
Enter the command to make automatic port calibration according to the currently
measured value.
at^scdin2="threshold_low",500
Manual calibration setting (minimum values). Setting options: 0 – 960.
at^scdin2="threshold_high",550
Manual calibration setting (maximum values). Setting options: 0 – 960.
at^scdin2="save"
Enter the command to save the changes.
at^scdin2?
Enter the command to display the currently set port values.
at^scdin2=?
Enter the command to display the port setting options.
S0 – Pulse Counting
The commands below are used for pulse counter state setting and reading out on S0
inputs.
at^scpulse1="state"
Enter the command to know the current states of the input 1 counter.
COUNTING- counting in progress
STOPPED- counting stopped
at^scpulse1="get_value"
Enter the command to read out the counter state.
at^scpulse1="set_value",100