Chapter 6 Basic Setting
XS3900-48F User’s Guide
71
The following table describes the labels in this screen.
Table 13
Basic Setting > System Info
LABEL
DESCRIPTION
System Name
This field displays the descriptive name of the Switch for identification purposes.
Product Model
This field displays the model number of the Switch.
ZyNOS F/W
Version
This field displays the version number of the Switch 's current firmware including the date
created.
Ethernet
Address
This field refers to the Ethernet MAC (Media Access Control) address of the Switch.
Hardware Monitor
Temperature
Unit
The Switch has temperature sensors that are capable of detecting and reporting if the
temperature rises above the threshold. You may choose the temperature unit (Centigrade or
Fahrenheit) in this field.
Temperature
CPU, PHY, and MAC refer to the location of the temperature sensors on the Switch printed
circuit board.
Current
This shows the current temperature at this sensor.
MAX
This field displays the maximum temperature measured at this sensor.
MIN
This field displays the minimum temperature measured at this sensor.
Threshold
This field displays the upper temperature limit at this sensor.
Status
This field displays Normal for temperatures below the threshold and Error for those above.
Fan Speed
(RPM)
A properly functioning fan is an essential component (along with a sufficiently ventilated,
cool operating environment) in order for the device to stay within the temperature threshold.
Each fan has a sensor that is capable of detecting and reporting if the fan speed falls below
the threshold shown.
Current
This field displays this fan's current speed in Revolutions Per Minute (RPM).
MAX
This field displays this fan's maximum speed measured in RPM.
MIN
This field displays this fan's minimum speed measured in RPM. “<41" is displayed for speeds
too small to measure (under 2000 RPM).
Threshold
This field displays the minimum speed at which a normal fan should work.
Status
Normal indicates that this fan is functioning above the minimum speed. Error indicates that
this fan is functioning below the minimum speed.
Voltage (V)
The power supply for each voltage has a sensor that is capable of detecting and reporting if
the voltage falls out of the tolerance range.
Current
This is the current voltage reading.
MAX
This field displays the maximum voltage measured at this point.
MIN
This field displays the minimum voltage measured at this point.
Threshold
This field displays the percentage tolerance of the voltage with which the Switch still works.
Status
Normal indicates that the voltage is within an acceptable operating range at this point;
otherwise Error is displayed.
Summary of Contents for XS-3900-48F
Page 15: ...15 PART I User s Guide ...
Page 16: ...16 ...
Page 48: ...Chapter 2 Tutorials XS3900 48F User s Guide 48 ...
Page 62: ...Chapter 4 The Web Configurator XS3900 48F User s Guide 62 ...
Page 63: ...63 PART II Technical Reference ...
Page 64: ...64 ...
Page 227: ...Chapter 26 VLAN Mapping XS3900 48F User s Guide 227 ...
Page 320: ...Appendix A Common Services XS3900 48F User s Guide 320 ...
Page 332: ...Index XS3900 48F User s Guide 332 ...