Chapter 2 Tutorials
XS3900-48F User’s Guide
44
7
Click Add to save the settings to the run-time memory. Settings in the run-time memory are lost
when the Switch’s power is turned off.
8
Click the VLAN Status link in the Static VLAN screen and then the VLAN Port Setting link in the
VLAN Status screen.
9
Enter 200 in the PVID field for ports 1, 2, 3 and 10 to add a tag to incoming untagged frames
received on these ports so that the frames are forwarded to the VLAN group that the tag defines.