ALC1224 User’s Guide
Diagnostics
8-3
Table 8-3 Log Messages
LOG MESSAGE
TYPE
DESCRIPTION
Session Begin!
INFO
A console, telnet or FTP session has begun (see the <process> field for
the type of session).
Session End!
INFO
A console telnet or FTP session has terminated (see the <process> field
for the type of session).
Incorrect Password! WARN
Someone attempted to use the wrong password to start a console, telnet
or FTP session (see the <process> field for the type of session).
Received Firmware
Checksum Error!
WARN
A checksum error was detected during an attempted firmware upload (the
<process> field shows whether the web configurator or FTP was used).
Received Firmware
Size too large!
WARN
The file size was too large with an attempted firmware upload (the
<process> field shows whether the web configurator or FTP was used).
Received Firmware
Invalid!
WARN
Someone attempted to upload a firmware file with a wrong identity (the
<process> field shows whether the web configurator or FTP was used).
Received File
<file>!
INFO
A file was uploaded to the ALC1224 by FTP.
<file>
- received file’s name
THERMO OVER
TEMPERATURE:
dev:<id>
threshold:<threshol
d>(degree C)
value:<temp>(degree
C)!
WARN
The temperature was too high at one of the three temperature sensors.
<id>
- 0: sensor near the power module
- 1: sensor near the CPU
- 2: sensor near the ADSL chipset
<threshold> - threshold temperature
<temp> - temperature when the entry was logged
THERMO OVER
TEMPERATURE
released: dev:<id>
threshold:<threshol
d>(degree C)
value:<temp>(degree
C)!
INFO
The temperature at one of the three temperature sensors has come back
to normal.
<id>
- 0: sensor near the power module
- 1: sensor near the CPU
- 2: sensor near the ADSL chipset
<threshold> - threshold temperature
<temp> - temperature when the entry was logged
THERMO OVER
VOLTAGE:
nominal:<nominal>(m
V) value:<voltage>
mV)!
WARN
The line card’s voltage went outside of the accepted operating range.
<nominal>
- nominal voltage of the DC power
<voltage>
- voltage of the DC power when logged
THERMO OVER VOLTAGE
released:
nominal:<nominal>(m
V) value:<voltage>
(mV)!
INFO
The line card’s voltage is back inside the accepted operating range.
<nominal>
- nominal voltage of the DC power
<voltage>
- voltage of the DC power when logged
8.4 Diagnostic DSL Screen
Click
DSL
in the
Diagnostic
screen to open the
ALC DSL Line Diagnostic
screen.
Summary of Contents for ALC1224
Page 1: ...ALC1224 ADSL Line Card Version 3 50 LK 0 LV 0 August 2004 User s Guide...
Page 6: ......
Page 16: ......
Page 18: ......
Page 30: ......
Page 32: ......
Page 38: ...ALC1224 User s Guide 2 6 Web Configurator Introduction Figure 2 6 ALC Edit Port Setup...
Page 68: ...ALC1224 User s Guide 4 10 Virtual Channel Management...
Page 70: ......
Page 76: ......
Page 86: ......
Page 94: ......
Page 96: ......
Page 128: ......
Page 129: ...Index V Part V Index This part provides an index of important terms...
Page 130: ......
Page 136: ...ALC1224 User s Guide F Index X XMODEM upload 9 2...