6–9
RDL REQUEST
LLINE TX POWER (Leased LINE)
PHONE JACK
MAKE/BREAK RATIO
SECONDARY CHANNEL (Optional feature)
GRANT
AT&T4
Accepts remote digital loopback test request
from remote modem. Must be set when remote
configuration is needed.
+
DENY
AT&T5
Ignores remote digital loopback test request
from remote modem. (Default)
0
to
-15
dBm
AT*P0
...
AT*P15
Selects transmission power from 0 dBm to -15
dBm. Default is -9 dBm. Effective in leased-line
operation only. Select in the range of -12 to -27
dBm when
S35b3
is set. The Omni 288P and
288S have a maximum TX power of -9dBm
and -3dBm, respectively.
+
SINGLE RJ11
AT&J0
RJ11 permissive telephone jack for dial-up line.
(Default)
MULTIPLE
RJ12/13
AT&J1
The modem supports A/A1 multi-extension tele-
phone.
+
39% / 61%
AT&P0
For use in the USA/Canada and some other
countries. (Default)
33% / 67%
AT&P1
For use in the UK and some other countries.
Note:
Controls the ratio of Make (Off-hook) and Break (On-hook) interval
for pulse dialing. Some countries have
AT&P1
as default.
+
DISABLED
AT*S0
Secondary channel is disabled. (Default)
ENABLED
AT*S1
Secondary channel is enabled.
Note:
This option is available for models with the
N suffix (networking).
Summary of Contents for 2864 Series
Page 1: ...i 2864 Series Modem User s Manual Document No 8406 Rev 1 0 ZyXEL COMMUNICATIONS CORPORATION...
Page 8: ...viii...
Page 26: ...1 10...
Page 42: ......
Page 50: ...3 14...
Page 66: ...5 10...
Page 110: ...8 24...
Page 128: ...10 6...
Page 134: ...11 6...
Page 148: ...13 10...
Page 204: ...16 28...
Page 224: ...21 4...
Page 230: ...23 4...
Page 234: ...24 4...
Page 246: ...A 2...
Page 248: ...B 2...
Page 252: ...D 2...
Page 256: ...E 4...
Page 267: ......