16–16
The DCE returns the
VCON
result code (returns
OK
if
S48.5=1
) if the DCE ac-
cepts this command, or it returns the ERROR result code if the <device> value is
not permitted.
•
AT+V
LS
?
The DCE will return the current I/O device followed by the
OK
result code.
•
AT+V
LS
=?
The DCE will return permitted I/O devices. The response is:
0,1,2,8,16
OK
•
AT+V
RA
=<
interval
>
The DCE only uses this command in a call origination transaction. This command
sets the amount of time the DCE shall wait between ringbacks before the DCE can
assume that the remote station has gone off-hook. The default value is 70 (7 sec-
onds). The range of <interval> is from 0 to 255. The units are 0.1 seconds. A value
of zero forces the DCE to return the
OK
result code immediately after the first ring-
back.
The <interval> subparameter refers to the silence interval length between the end of
one ring interval and the start of the next ring interval. The DCE returns the
OK
re-
sult code if the DCE accepts this command, or it returns the
ERROR
result code if
the <interval> is out of range.
•
AT+V
RA
?
The DCE will return the current Ringback Goes Away Timer interval value, fol-
lowed by the OK result code.
•
AT+V
RA
=?
The DCE will return the permitted interval of the Ringback Goes Away Timer. The
response is:
0-255
OK
•
AT+V
RN
=<
interval
>
The DCE only uses this command in a call origination transaction. This command
sets the amount of time the DCE will wait looking for a ringback. If the DCE does
not detect a ringback within this time period, the DCE assumes that the remote
station has gone off-hook, and returns an
OK
result code.
A
+VRN
setting higher than the value in the
S7
register means that only the
S7
timer is in effect. The range of <
interval
> is from 0 to 255. The unit is 1 sec-
ond. The default value is 10 (10 seconds). A value of zero forces the DCE to return
OK
immediately after dialing.
Summary of Contents for 2864 Series
Page 1: ...i 2864 Series Modem User s Manual Document No 8406 Rev 1 0 ZyXEL COMMUNICATIONS CORPORATION...
Page 8: ...viii...
Page 26: ...1 10...
Page 42: ......
Page 50: ...3 14...
Page 66: ...5 10...
Page 110: ...8 24...
Page 128: ...10 6...
Page 134: ...11 6...
Page 148: ...13 10...
Page 204: ...16 28...
Page 224: ...21 4...
Page 230: ...23 4...
Page 234: ...24 4...
Page 246: ...A 2...
Page 248: ...B 2...
Page 252: ...D 2...
Page 256: ...E 4...
Page 267: ......