ZDAS-16CA SERIES PROGRAMMING GUIDE
--------------------------------------------------------------------------------------------------------------------------------------------------------
PAGE
15
OF 19
4.25 Set Siren Sound Time
Format: 42+ time (2 bit)+
(confirm key)
Time: 00~40 Siren time=(00~40) x 30 seconds
Factory setting: 02 means 02 x 30=60seconds
4.26 Set Arm/Disarm with Siren Sound
Format: 61+0/1+
(0, no sound; 1, ARM with 1 sound, Dis-Arm with 2 sounds; Reset won’t
change the setting)
4.27 Timed Auto-Arm/ Auto-Disarm Time Setting
1. Time setting format: 45+ hour (2bit) + minute (2 bit) +
.
2. Auto-ARM Format: 46+ hour (2bit) +minute (2 bit) +
.
3. Auto-Disarm Format: 47+hour (2bit) +minute (2 bit) +
.
4.28 Time Adjusting Coefficient Setting
Format: 48 + Coefficient (00--99) +
Status: coefficient is 50 after reset make coefficient up if time is too quick (more than 50)
make coefficient down if time is too slow (less than 50)
Note: Time adjusting coefficient is for adjusting the difference per second between system time
and the current time. (Each interval coefficient is 1/150S)
4.29 Set Alarm if AC power Failure
Format: Press 62+0/1+
(1. sound; 0. no sound; Factory setting: 0)
4.30 Checking Time Setting
Format: 25+ AC power checking time(1 bit)+ Battery voltage checking time(1 bit)+ Telephone
line checking time(1 bit) +
Time: 0=1S, 1=2S, 2=5S, 3=10S, 4=30S, 5=180 Seconds
(Factory setting: AC power checking time: 3; Battery voltage checking time: 3; Telephone line
checking time: 0)
4.31 Zone Sensitivity Setting
Format: 26+ Zone Number(2 bit) + Sensitivity(1 bit) +
(Zone number: 01~16)
Sensitivity: 0=40 Milli-Seconds, 1=80MS, 2=200MS, 3=500MS, 4=1S, 5=2S, 6=5S (Factory
setting: 2)
4.32 Delay Power Off of Low Battery
Format: 28+ P
ower off delay time (3 bit) +
Power off delay time: 000~255 minutes
(Factory setting: 30 minutes)
4.33 Zone Anti-false Report Setting
Format: 29+ Zone triggered times (1bit) + Stop Alarm time (2 bit) +
Zone triggered times: 0~9(Means the maximum continuous triggering times per hour) (Factory
setting: 5)
Stop Alarm time: 00~16 hours (Factory setting: 06)
Note: Stop alarm time means how long the system will be activated again after the zones
reached the maximum triggering times.
4.34 Open/Close Keypad Anti-Tamper Function
Format: 63+0/1+
(1. open, 0. close. Factory Setting: 0)
4.35 Keypad Line Cutting Inspection
Format: 64+0/1+
(1. open, 0. close. Factory Setting: 0)
4.36 Set Center Precision