ZDAS-16CA SERIES PROGRAMMING GUIDE
--------------------------------------------------------------------------------------------------------------------------------------------------------
PAGE
16
OF 19
Format: 65+ precision value (1 bit)+
(Value: 0~9. Factory Setting: 6)
4.37 Set Center Signal Time
Format: 66+ Signal time (1 bit) +
(Time: 0~9. Factory Setting: 6)
4.38 Set Dial-up Rounds
Format: 69+ dial rounds (1-9) +
(Factory Setting: 9)
4.39 Set Output Module
* 8 way output time:
Format: 35 + Way Number (1~8) + Second (4 bit) +
Seconds: 0000—9999 seconds (Factory setting: 60 seconds)
* 8 way output conditions:
Format: 36 + Way Number (1~8) + Condition 1(2 bit) + Condition 2(2 bit) +
(Factory
setting: 0)
8 way output corresponding conditions: 00 means siren following, 01~16 is corresponding
Zone alarm output
17 means Zone alarm output
18 means press emergency
key
19 means ARM
20 means DIS-ARM
21 means ARM with output, and DIS-ARM without
output
Remote control of module output:
Format: * + way number(1bit) + status(1bit) + #
(Way number: 1~8, means 1
st
to 8
th
way, status: 1 open output, 2 close output)
For example: under remote control status, * +1 +1 + # (means open output of the 1
st
way)
* +1 + 0 + # (means close output of the 1
st
line)
4.40 View The Recording Event Log
Operating: 99 + 2 +
(Enter viewing events status)
Record method
:
+
※ ※
+
+
+
+
+
+
+
+
※ ※
※ ※
※ ※
※ ※
(
number)
(
days)
(
things
)
(
hour
)
(
minute
)
Events: 01-16 is zone alarm,30 is Arming, 40 is Disarming, press
to view the next event
under viewing events status.
4.41 PROG GSM function
(only for ZDAS-16CA-16G)
Insert a valid GSM SIM card into the SIM socket, then plug the GSM antenna into the terminator. If
the system works well, GSM working indicator & Mainboard working indicator on PCB will be
regular flash, and the Status indicator on keypad will light on.
Programming
Note: The following 0 ~ 5 operating is under setting status: (F4)
0. Open Remote Control:
71 + status (1bit) + F4 (Confirm key)
Status: 0 Remote Control Off, 1 Remote Control On (Factory Setting: 0 Off)
1. Set phone format for SMS alarm or Call alarm:
77 + group of telephone number (1 bit) + status (1 bit) + F4 (confirm key).
Status: 4 SMS alarm; 5 Call alarm; (Factory default setting: 2nd to 7th group is 5)