59 / 138
Identification: MD-AL-GI-00
Rev. 1.1 of 15/03/2021 - Application: GID
User’s Manual 3PH 50000TL-60000TL-V1
Rev. 1.1 15/03/2021
condition until normal operation is restored.
Alarm configuration
The relay switches over when it records an alarm (Error) or
temporary warning which was previously selected by the user via the
PC. The contact remains open (or closed) until the inverter detects an
error or warning other than those selected in the menu; when the
inverter displays an error or warning other than those selected, it
changes state and, therefore, closes (or opens). The relay remains
active with respect to its standby condition until the alarm or warning
disappears.
Disabling the relay
The control function is not permitted.
Enable country
Select “7. Enable country” and press “OK” to enter the menu for enabling the selection of the country code.
The display will show “Enter PWD!”, press “OK” to enter the password. Enter the password “0001” using the
“Up” and “Down” keys to select the number and “OK” to move to the next one, and confirm. If the display
shows “Incorrect, try again!” press the “Back” key and enter the password again. When the password entered
is correct, you can enter the menu.
This operation must be carried out if you want to change the Country code and it has not been changed
during the last 24 hours of operation of the inverter.
Set Energy
Select “8. SetEnergy” and press “OK” to enter the menu for setting the energy already produced by the
photovoltaic system. The display will show “Enter PWD!” Press “OK” to enter the password “0001” using the
“Up” and “Down” keys to select the number and “OK” to move to the next digit. If the display shows
“Incorrect, try again!” press the “Menu/Back” key and enter the password again. When the password has
been entered correctly, you can enter the menu. You can now set the amount of energy already produced by
the system before installing the current inverter, which is visible from the main interface.
Modbus address
Select “9. ModBusAddress” and press “OK” to enter the menu for selecting the communication address. Use
the “Up” and “Down” keys to select the number and “OK” to move to the next one, and confirm. After setting
the address, press “OK.”
The Modbus address indicates the address used by the inverter to send its data to the monitoring server.
Address 01 is used for single inverters; to extend the monitoring to multiple inverters, use progressive
communication addresses.
Note: make sure that the address entered is never 00, because this setting would exclude the
possibility of communication between the inverter and the Wi-Fi network or RS485. port.